Table of Contents

Search

  1. Preface
  2. Proactive Monitoring for PowerCenter Operations
  3. Monitoring PowerCenter Operations
  4. Manage Objects
  5. Proactive Monitoring Reports
  6. Proactive Monitoring SNMP Alerts
  7. Proactive Monitoring Watchlists
  8. Proactive Monitoring Topics
  9. Proactive Monitoring Services
  10. Proactive Monitoring Templates and Rules
  11. Proactive Monitoring Responses
  12. Appendix A: Troubleshooting
  13. Appendix B: Topic Properties Reference
  14. Appendix C: Frequently Asked Questions
  15. Appendix D: Glossary

Operations User Guide

Operations User Guide

Proactive Monitoring Responses

Proactive Monitoring Responses

The response is where you define how you want responses if the rule’s event matches the rule condition. In addition to simple notification response, such as send an email or text message, you can configure a response to function like an action.
You can configure to send responses to a single user or groups of users through email or
Real-Time Alert Manager
user interface.
The following table lists the predefined responses that are available by default upon installing
Proactive Monitoring for PowerCenter Operations
:
Name
Response Type
Description
State
PowerCenter RTAM Alert
RTAM
Sends alerts to Real-Time Alert Manager.
Deployed
PowerCenter Notification Response
Event Transformer
Transforms events to notification events.
Deployed
PowerCenter Email Response
Email
Sends email to the specified users with content based on the response properties.
Deployed
PowerCenter Alert Recorder Response
SQL
Records alerts to the RulePoint database.
Deployed
PowerCenter Alert History Purge Response
SQL
Purges alert history older than the specified number of days.
Deployed
PowerCenter Web Service Hub Workflow Control Response
PMPC WSH Workflow Controller
Sends start, stop, restart, abort, schedule, unschedule, or recover operation to control the PowerCenter workflow.
Stop workflow does not abort the workflow but stops the workflow. To abort, use the abort workflow command exclusively.
Deployed
PowerCenter Runtime Stats Transformer Response
Event Transformer
Transforms events to run-time server, run-time workflow, run-time session, and run-time target events.
Deployed
PowerCenter completed sessions recorder response
SQL
Records completed sessions data in Proactive Monitoring database.
Deployed
PowerCenter completed sessions and workflows response
Event Transformer
Transforms events to pc_completed_sessions_trending and pc_completed_workflows_trending.
Deployed
PowerCenter completed workflows recorder response
SQL
Records completed workflows data in Proactive Monitoring database.
Deployed
PowerCenter Metadata Counts Response
SQL
Records aggregated count of sessions, workflows, mappings, and transformations into the Proactive Monitoring database.
Deployed
Process Monitor Table Update Response
SQL
Purges records from na_process_monitor table.
Deployed
PowerCenter completed workflows report recorder response
SQL
Records completed sessions data in Proactive Monitoring database for reports.
Deployed
PowerCenter completed sessions report recorder response
SQL
Records completed sessions data in Proactive Monitoring database for reports.
Deployed
PowerCenter running session workflow count recorder response
SQL
Records running session workflow count data in Proactive Monitoring database for reports
Deployed
SNMP v2 Response
SNMP Response
Sends SNMP traps as an alert to SNMP Trap Receiver. To enable sending notifications as SNMP traps, deploy the rule, PC_S7 SNMP Notification.
Draft

0 COMMENTS

We’d like to hear from you!