Table of Contents

Search

  1. Preface
  2. Part 1: On-Prem Operations
  3. Part 2: Parameter and Element Reference
  4. Appendix A: Geocode Countries
  5. Appendix B: Reverse Geocoding Coverage
  6. Appendix C: Certified Mode Values

On-Premises Developer Guide

On-Premises Developer Guide

Certified Mode Verification for France Addresses

Certified Mode Verification for France Addresses

To verify France addresses in certified mode, install the
FRA_ADV_VRF_BIA_000_6_1_0.MD6
database with valid license keys.
For SNA certified processing, enter addresses in the six-line PostalFormattedAddressLines format, including empty lines wherever a part of the address is missing.
The following table lists the values for the six-line PostalFormattedAddressLines format:
Postal Formatted Address Lines
Value
Line 1
ORGANIZATION IDENTIFICATION or IDENTITY OF THE ADDRESSEE
Line 2
INDIVIDUAL IDENTIFICATION (Company Contact) or DELIVERY POINT ACCESS INFORMATION (SubBuilding)
Line 3
DELIVERY POINT LOCATION (Building)
Line 4
STREET NUMBER or PLOT and THOROUGHFARE
Line 5
DELIVERY SERVICE or THOROUGHFARE COMPLEMENTARY IDENTIFICATION
Line 6
POSTCODE and LOCALITY or CEDEX POSTCODE and DISTRIBUTION AREA INDICATOR
SNA certification supports 7-bit ASCII data, and certified output does not include diacritics or mixed-case values.
Informatica also provides the
FRA_ADV_VRF_BIA_001_6_1_0.MD6
file, which you can use to deliver addresses with diacritics and in mixed case in batch and interactive modes. If the 001 data file is not available, batch and interactive processing can succeed if the 000 data file is present.
The
FRA_ADV_VRF_BIA_000_6_1_0.MD6
file is the default file for France in the batch and interactive file data set.

0 COMMENTS