Table of Contents

Search

  1. Abstract
  2. Informatica Installation
  3. Informatica Upgrade
  4. Informatica Closed Enhancements
  5. Informatica Fixed Limitations
  6. Informatica Known Limitations
  7. Informatica Third-Party Limitations
  8. Informatica Global Customer Support

Informatica Connector Toolkit Known Limitations

Informatica Connector Toolkit Known Limitations

The following table describes known limitations:
CR
Description
441871
When you test the metadata, after you import an adapter project and edit the metadata, the metadata test fails.
Workaround: Delete the
build
and
sdk
directories from the adapter project workspace and regenerate code for the connection, type system and native metadata.
441291
The Informatica Connector Toolkit Installer is not available for Linux 64 and AIX 64 platforms.
Workaround: To manually install the Informatica Connector Toolkit on Linux or AIX platform, refer to the
Installing Informatica Connector Toolkit on Linux or AIX
section in the Informatica Connector Toolkit Developer Guide.
438209
When you use
Datetime
data type in a filter operation, you cannot test the read capability of the adapter.
Workaround: Use the Informatica Developer Client to test the
Datetime
data type.
438203
When you create native metadata objects with the same name but different letter case, the code generation fails.
Workaround: Use different names for different native metadata objects.
435998
When you edit a connection attribute that has dependent fields, the test connection wizard does not display the changes made to the connection attribute.


Updated October 25, 2018