Table of Contents

Search

  1. Abstract
  2. Installation and Upgrade
  3. Fixed Limitations and Closed Enhancements (10.1.1 HF2)
  4. 10.1.1 HF2 Known Limitations
  5. 10.1.1 HotFix 1 Fixed Limitations and Closed Enhancements
  6. 10.1.1 HotFix 1 Known Limitations
  7. 10.1.1 Update 2 Fixed Limitations and Closed Enhancements
  8. 10.1.1 Update 2 Known Limitations
  9. 10.1.1 Update 1 Fixed Limitations and Closed Enhancements
  10. 10.1.1 Update 1 Known Limitations
  11. 10.1.1 Fixed Limitations and Closed Enhancements
  12. 10.1.1 Known Limitations
  13. Informatica Global Customer Support

Applying or Rolling Back the Client HotFix in Silent Mode

Applying or Rolling Back the Client HotFix in Silent Mode

To apply the hotfix in silent mode, create the
SilentInput.properties
file and then run the installer with the file.
Informatica provides a sample properties file, called
SilentInput_hotFix.properties
, that includes the parameters that are required by the installer. The following example shows the contents of the file:
########################################################## # Informatica Installer Build details # Copyright (c) 1993-2017 Informatica LLC # This software contains confidential and proprietary # information of Informatica LLC # All Rights Reserved. ########################################################## # Use the following guidelines when editing this file: # * Use this file to install without user interaction. # * After you create the properties file, save the file with the name SilentInput.properties. # * Any error condition that leads to failure, such as an invalid # installation directory, generates a log file in the user home directory. # For example: c:\silentErrorLog<time_stamp>.log # This version does not support big data products. # If you upgrade to this version, the big data functionality will not be available. # Set UPGRADE_WITHOUT_BIGDATA=1 if you want to continue with the upgrade. UPGRADE_WITHOUT_BIGDATA=0 # * The USER_INSTALL_DIR variable must point to a valid directory with write # permissions enabled. USER_INSTALL_DIR=c:\Informatica\10.1.1 ####### # After you create the properties file, save the file with the name SilentInput.properties and # run the silent installer to perform the Informatica client installation. #######
  1. Go to the root of the directory that contains the installation files.
  2. Locate the
    SilentInput_HotFix.properties
    file.
  3. Back up the file before you modify it.
  4. Use a text editor to open the file and modify the values. The following table describes the installation properties that you can modify:
    Property Name
    Description
    INSTALL_TYPE
    Indicates whether to apply the hotfix or roll back the hotfix. If the value is 0, the installer applies the hotfix to the current Informatica client installation. If the value is 1, the installer rolls back the current hotfix.
    UPGRADE_WITHOUT_BIGDATA
    Informatica does not support big data products for version 10.1.1 HotFix 2. If you want to install or upgrade to this version, the big data functionality will not be available.
    Set the value to 1, to continue with client installation.
    Set the value to 0, to quit the client installation.
    USER_INSTALL_DIR
    Directory for the Informatica installation on which to apply or roll back the hotfix.
    To apply the hotfix to the Informatica clients, enter the absolute path for the directory in which the current version of the Informatica clients is installed.
    To roll back the hotfix, enter the absolute path for the directory in which the current version of the Informatica clients is installed.
  5. Save the properties file with the name SilentInput.properties.
  6. Go to root of the client installer directory.
  7. Verify that the directory contains the
    SilentInput.properties
    file that you edited and saved.
  8. To apply or roll back the hotfix on Windows, double-click the
    silentInstallHotFix.bat
    .
    If you apply a hotfix, the installer copies the Informatica files to the installation directory. If you roll back a hotfix, the installer removes the last hotfix and restores the previous version of Informatica.
  9. Verify that the hotfix or rollback completed successfully.
  10. Complete the post-installation tasks.


Updated June 23, 2020