Table of Contents

Search

  1. Abstract
  2. Installation and Upgrade
  3. 10.2 HF1 Fixed Limitations and Closed Enhancements
  4. 10.2 HF1 Known Limitations
  5. 10.2 Fixed Limitations and Closed Enhancements
  6. 10.2 Known Limitations
  7. Emergency Bug Fixes Merged into 10.2
  8. Informatica Global Customer Support

Developer Tool Fixed Limitations (10.2)

Developer Tool Fixed Limitations (10.2)

Review the Release Notes of previous releases for information about previous fixed limitations.
The following table describes fixed limitations:
Bug
Description
PLAT-18475
After you back up a domain and restore it, the Informatica Services do not start up.
PLAT-18039
You cannot preview the data for a transformation when the following conditions are true for a mapping:
  • A pipeline splits at a single group and rejoins at a single group.
  • The filter condition in a Filter transformation after the pipeline returns FALSE, filtering all the data from the pipeline.
PLAT-17853
A logical error in metadata synchronization might occur when you open a project in the Developer tool. The error might not load transformations and mapplets properly. It might also cause mapplets to show errors for certain ports and no longer be connected to other transformations in the workflow.
If the logical error occurs and the user tries to import certain exported metadata into the Developer tool, the Developer tool displays a message that an unknown error has occurred to avoid exacerbating the issue.
PLAT-17705
When you import metadata from an IBM DB2 z/OS source, the Developer tool displays the schema name as default instead of the schema name associated with the user. The Developer tool also duplicates columns that are present in multiple schemas.
PLAT-17650
If you use the DB2 JDBC drivers to read data from IBM DB2 z/OS databases, data preview fails.
PLAT-17640
When you generate a mapping from an SQL query and edit the filter condition in the logical data object read mapping, data preview of Read transformation fails with the following error:
[LDTM_0042] The mapping cannot be validated because of the following errors: [The connection for data object [object name] cannot be empty.
PLAT-16137
When you install Developer tool on Windows, some JAR files are not installed.
PLAT-15579
When you import an object from an XML file into the Developer tool, a message is not written to the Developer tool log file.
PLAT-14011
If you install the SQL Server JDBC driver on a virtual machine, you cannot use the driver to connect to Azure SQLServer. (457076)
PLAT-13743
When you import Teradata or Netezza objects from PowerCenter to the Developer tool, objects are converted as Teradata or Netezza objects by default. (457283)
OCON-9885
If you configure ODBC on Windows to connect to a Microsoft SQL Server database, mappings terminate randomly.
OCON-9300
Dynamic mappings fail intermittently with the following error message:
[com.informatica.sdk.dtm.InvalidMappingException] Exception Message: [[LDTMEXP_0029] Failed to process mapping because of following reason [null].].
OCON-9121
If you enable high precision, set NLS_LANG to a non-English locale on the machine that runs the Informatica services, and read decimal data from an Oracle source, a data overflow or conversion error occurs.
OCON-10019
If the database service goes down when you run a mapping to write large volumes of data to a Microsoft SQL Server database, the mapping stops responding.
IDQ-2741
Copy and paste operations on a reference table object might fail.
BDM-6790
Export to PowerCenter fails because an Oracle target contains fields of the String data type instead of the Varchar data type.


Updated June 29, 2020