Table of Contents

Search

  1. Abstract
  2. Informatica Installation
  3. Informatica Upgrade
  4. 10.1 Fixed Limitations and Closed Enhancements
  5. 10.1 Known Limitations
  6. Informatica Global Customer Support

Data Transformation Known Limitations

The following table describes known limitations:
CR
Description
455003
A Data Processor transformation with hierarchical input and relational output, or relational input and hierarchical output, and with a Decimal38 output port, might fail in a mapping. A Hierarchical to Relational transformation with a Decimal38 output port, or a Relational to Hierarchical transformation with the same, might also fail in a mapping.
Workaround:
Do not use Decimal38 for any output port in these transformations.
CM-7722
When a Data Processor transformation transforms data into JSON output, the control characters are not escaped with the
\u
character.
CM-7720
HIPAA validation is not supported for Edifecs version 6.x in a Data Processor transformation with a HIPAA Library package.
CM-7693
A Data Processor transformation with JSON output replace unicode characters that are not valid with binary zero, instead of replacing with zero and a hexadecimal identifier.
CM-7692
An XMLStreamer in a Data Processor transformation fails to process documents with a DOCTYPE declaration.
CM-7691
When a Data Processor transformation transforms data into JSON output for characters 0-31, the control characters are not escaped with the
\u
character.
B2BT-377
A Data Transformation project fails to process an HTTPS URL in a Linux environment.