Table of Contents

Search

  1. Abstract
  2. Installation and Upgrade
  3. 10.2 HF1 Fixed Limitations and Closed Enhancements
  4. 10.2 HF1 Known Limitations
  5. 10.2 Fixed Limitations and Closed Enhancements
  6. 10.2 Known Limitations
  7. Emergency Bug Fixes Merged into 10.2
  8. Informatica Global Customer Support

Informatica Connector Toolkit Known Limitations (10.2)

Informatica Connector Toolkit Known Limitations (10.2)

The following table describes known limitations:
Bug
Description
OCON-7420
When you create native metadata objects with the same name but different letter case, the code generation fails.
Workaround: Use different names for different native metadata objects. (438203)
OCON-6520
When you create an attribute for a native metadata object of type String with
Max Length
set to 255, the
Max Length
of the attribute is set incorrectly to 4000 after code generation.
OCON-10257
On Linux, when you test the read or write operation, the test fails with the following error message:
java.lang.UnsatisfiedLinkError
OCON-10252
On Linux, code generation takes a long time.


Updated June 29, 2020