Table of Contents

Search

  1. Informatica Bug Tracking System Change
  2. PowerExchange for Amazon Redshift
  3. PowerExchange for Amazon S3
  4. PowerExchange for Cassandra
  5. PowerExchange for DataSift
  6. PowerExchange for Facebook
  7. PowerExchange for Greenplum
  8. PowerExchange for HBase
  9. PowerExchange for HDFS
  10. PowerExchange for Hive
  11. PowerExchange for JD Edwards EnterpriseOne
  12. PowerExchange for LDAP
  13. PowerExchange for LinkedIn
  14. PowerExchange for MapR-DB
  15. PowerExchange for Microsoft Azure Blob Storage
  16. PowerExchange for Microsoft Azure SQL Data Warehouse
  17. PowerExchange for Microsoft Dynamics CRM
  18. PowerExchange for MongoDB
  19. PowerExchange for Netezza
  20. PowerExchange for OData
  21. PowerExchange for Salesforce
  22. PowerExchange for SAP NetWeaver
  23. PowerExchange for Tableau
  24. PowerExchange for Teradata Parallel Transporter API
  25. PowerExchange for Twitter
  26. PowerExchange for Web Content-Kapow katalyst
  27. Informatica Global Customer Support

PowerExchange Adapters for Informatica Release Notes

PowerExchange Adapters for Informatica Release Notes

PowerExchange for SAP NetWeaver Known Limitations (10.1.1)

PowerExchange for SAP NetWeaver Known Limitations (10.1.1)

The following table describes known limitations:
Bug
Description
PLAT-14818
When you enter FTP and SFTP details in an SAP connection and then clear the
Use FTP
and
Use SFTP
options, the details that you entered are cleared from the dialog box. This issue occurs when you create an SAP connection in Informatica Administrator and Informatica Developer. (407606)
PLAT-14816
In Informatica Administrator, after you create a successful SNC-enabled SAP connection, if you edit the connection and specify incorrect values for the SNC library path, the Administrator tool validates the connection as successful. It does not display any error. (407551)
PLAT-14748
When you use a 7.x data source to write data to SAP BW and the data source contains columns of the DATS and TIMS data types, the mapping fails. (442883)
PLAT-14743
On Windows 64-bit operating systems, when you run a mapping with the deprecated SAP data object read operation, the mapping fails.
Workaround: Download the following library files from the SAP Service Marketplace:
  • icudt34.dll
  • icuin34.dll
  • icuuc34.dll
Copy the files to the following directory and run the mapping again:
<Informatica installation directory>/services/shared/bin
To test SAP connections from Informatica Administrator, you must also copy the files to the following directory:
<Informatica installation directory>/server/bin
(441761)
PLAT-14705
When you add an SAP Table data object read operation as a lookup in a mapping, and configure the lookup condition based on a transparent table and a cluster or pool table, the mapping fails. (432043)
PLAT-14701
When you add an SAP Table data object read operation as a lookup in a mapping, and configure the lookup condition based on a column of the LCHAR data type, the Data Integration Service does not apply the lookup condition. The Data Integration Service also writes corrupted data into the target. (431278)
PLAT-14686
In an SAP Table data object read operation, when you define a sort condition for cluster and pool tables and run a mapping, the mapping fails. (428266)
PLAT-14674
While scheduling an InfoPackage in SAP BW, if you specify an incorrect folder name, no validation error is displayed. Instead, a message appears stating that the data has been requested from SAP. (423522)
OCON-936
In Informatica Administrator, while deploying an application to a Data Integration Service, the physical data object type is incorrectly displayed for the following SAP data objects:
  • SAP Table data object
  • SAP BW OHS Extract data object
  • SAP BW Load data object
(428770)
OCON-6754
When you add a space at the end of the FTP host name in an SAP connection and read data from SAP tables, the mapping fails.
OCON-520
When you parameterize an SAP Table data object read operation property, you cannot define a precision that is higher than 28 for decimal data types. (435156)