Table of Contents

Search

  1. Abstract
  2. PowerExchange for Amazon Redshift
  3. PowerExchange for Amazon S3
  4. PowerExchange for Cassandra
  5. PowerExchange for DataSift
  6. PowerExchange for Facebook
  7. PowerExchange for Greenplum
  8. PowerExchange for HBase
  9. PowerExchange for HDFS
  10. PowerExchange for Hive
  11. PowerExchange for JD Edwards EnterpriseOne
  12. PowerExchange for LDAP
  13. PowerExchange for LinkedIn
  14. PowerExchange for MapR-DB
  15. PowerExchange for Microsoft Azure Blob Storage
  16. PowerExchange for Microsoft Azure Data Lake Store
  17. PowerExchange for Microsoft Azure SQL Data Warehouse
  18. PowerExchange for Microsoft Dynamics CRM
  19. PowerExchange for MongoDB
  20. PowerExchange for Netezza
  21. PowerExchange for OData
  22. PowerExchange for Salesforce
  23. PowerExchange for SAP NetWeaver
  24. PowerExchange for Snowflake
  25. PowerExchange for Tableau
  26. PowerExchange for Teradata Parallel Transporter API
  27. PowerExchange for Twitter
  28. PowerExchange for Web Content-Kapow Katalyst
  29. Informatica Global Customer Support

PowerExchange Adapters for Informatica Release Notes

PowerExchange Adapters for Informatica Release Notes

PowerExchange for SAP NetWeaver Known Limitations (10.2.1)

PowerExchange for SAP NetWeaver Known Limitations (10.2.1)

The following table describes known limitations:
Bug
Description
OCON-11528
In an SAP Table data object read operation, when you define a sort condition for cluster and pool tables and run a mapping, the mapping fails. (428266)
OCON-11497
When you add an SAP Table data object read operation as a lookup in a mapping, and configure the lookup condition based on a transparent table and a cluster or pool table, the mapping fails. (432043)
OCON-11454
When you enter FTP and SFTP details in an SAP connection and then clear the
Use FTP
and
Use SFTP
options, the details that you entered are cleared from the dialog box. This issue occurs when you create an SAP connection in Informatica Administrator and Informatica Developer. (407606)
OCON-11347
When you use a 7.x data source to write data to SAP BW and the data source contains columns of the DATS and TIMS data types, the mapping fails. (442883)
OCON-11286
On Windows 64-bit operating systems, when you run a mapping with the deprecated SAP data object read operation, the mapping fails.
Workaround: Download the following library files from the SAP Service Marketplace:
  • icudt34.dll
  • icuin34.dll
  • icuuc34.dll
Copy the files to the following directory and run the mapping again:
<Informatica installation directory>/services/shared/bin
To test SAP connections from Informatica Administrator, you must also copy the files to the following directory:
<Informatica installation directory>/server/bin
(441761)
OCON-11222
In Informatica Administrator, after you create a successful SNC-enabled SAP connection, if you edit the connection and specify incorrect values for the SNC library path, the Administrator tool validates the connection as successful. It does not display any error. (407551)
OCON-11217
When you add an SAP Table data object read operation as a lookup in a mapping, and configure the lookup condition based on a column of the LCHAR data type, the Data Integration Service does not apply the lookup condition. The Data Integration Service also writes corrupted data into the target. (431278)
OCON-11201
In Informatica Administrator, while deploying an application to a Data Integration Service, the physical data object type is incorrectly displayed for the following SAP data objects:
  • SAP Table data object
  • SAP BW OHS Extract data object
  • SAP BW Load data object
(428770)
OCON-11101
While scheduling an InfoPackage in SAP BW, if you specify an incorrect folder name, no validation error is displayed. Instead, a message appears stating that the data has been requested from SAP. (423522)
OCON-9961
If you create an SAP BW OHS mapping or workflow within a folder and do not specify the folder name when you set the OHD parameters, the Data Integration Service does not read any data. It also prints an incorrect OHS request ID in the mapping log.
OCON-9717
The Developer tool does not validate the values that you enter in the FTP fields of an SAP connection.
OCON-520
When you parameterize an SAP Table data object read operation property, you cannot define a precision that is higher than 28 for decimal data types. (435156)