Table of Contents

Search

  1. Abstract
  2. PowerExchange for Amazon Redshift
  3. PowerExchange for Amazon S3
  4. PowerExchange for Cassandra
  5. PowerExchange for DataSift
  6. PowerExchange for Facebook
  7. PowerExchange for Greenplum
  8. PowerExchange for Google BigQuery
  9. PowerExchange for HBase
  10. PowerExchange for HDFS
  11. PowerExchange for Hive
  12. PowerExchange for JD Edwards EnterpriseOne
  13. PowerExchange for LDAP
  14. PowerExchange for LinkedIn
  15. PowerExchange for MapR-DB
  16. PowerExchange for Microsoft Azure Blob Storage
  17. PowerExchange for Microsoft Azure Data Lake Store
  18. PowerExchange for Microsoft Azure SQL Data Warehouse
  19. PowerExchange for Microsoft Dynamics CRM
  20. PowerExchange for MongoDB
  21. PowerExchange for Netezza
  22. PowerExchange for OData
  23. PowerExchange for Salesforce
  24. PowerExchange for SAP NetWeaver
  25. PowerExchange for Tableau
  26. PowerExchange for Tableau V3
  27. PowerExchange for Teradata Parallel Transporter API
  28. PowerExchange for Twitter
  29. PowerExchange for Web Content-Kapow Katalyst
  30. Informatica Global Customer Support

PowerExchange Adapters for Informatica Release Notes

PowerExchange Adapters for Informatica Release Notes

PowerExchange for SAP NetWeaver Known Limitations (10.2)

PowerExchange for SAP NetWeaver Known Limitations (10.2)

The following table describes known limitations:
Bug
Description
OCON-11528
In an SAP Table data object read operation, when you define a sort condition for cluster and pool tables and run a mapping, the mapping fails. (428266)
OCON-11497
When you add an SAP Table data object read operation as a Lookup transformation in a mapping, and configure the lookup condition based on a transparent table and a cluster or pool table, the mapping fails. (432043)
OCON-11454
When you enter FTP and SFTP details in an SAP connection and then clear the
Use FTP
and
Use SFTP
options, the details that you entered are cleared from the dialog box. This issue occurs when you create an SAP connection in Informatica Administrator and Informatica Developer. (407606)
OCON-11286
On Windows 64-bit operating systems, when you run a mapping with the deprecated SAP data object read operation, the mapping fails.
Workaround: Download the following library files from the SAP Service Marketplace:
  • icudt34.dll
  • icuin34.dll
  • icuuc34.dll
Copy the files to the following directory and run the mapping again:
<Informatica installation directory>/services/shared/bin
To test SAP connections from Informatica Administrator, you must also copy the files to the following directory:
<Informatica installation directory>/server/bin
(441761)
OCON-11222
In Informatica Administrator, after you create a successful SNC-enabled SAP connection, if you edit the connection and specify incorrect values for the SNC library path, the Administrator tool validates the connection as successful. It does not display any error. (407551)
OCON-11201
In Informatica Administrator, while deploying an application to a Data Integration Service, the physical data object type is incorrectly displayed for the following SAP data objects:
  • SAP Table data object
  • SAP BW OHS Extract data object
  • SAP BW Load data object
(428770)
OCON-9961
If you create an SAP BW OHS mapping or workflow within a folder and do not specify the folder name when you set the OHD parameters, the Data Integration Service does not read any data. It also prints an incorrect OHS request ID in the mapping log.
OCON-9717
The Developer tool does not validate the values that you enter in the FTP fields of an SAP connection.
OCON-520
When you parameterize an SAP Table data object read operation property, you cannot define a precision that is higher than 28 for decimal data types. (435156)