PowerExchange Adapters for Informatica
- PowerExchange Adapters for Informatica 10.4.1
- All Products
CR
| Description
|
---|---|
OCON-23260
| When you configure multiple pre-SQL or post-SQL queries in a mapping and if there is a space after the last query that ends with the ; character, the mapping fails.
|
OCON-21723
| When you configure pushdown optimization in a mapping to write data to Snowflake, the update as update, update else insert, and delete operations are not supported.
|
OCON-22177
| When you run a mapping on the Spark engine to write data to a Snowflake target and the target table and column names are not in uppercase letters, the mapping fails.
|
OCON-16608
| When you run a mapping on the Spark engine to write data to a Snowflake target, and the data contains the Binary data type, the mapping fails.
|