Table of Contents

Search

  1. Preface
  2. Summary of PowerExchange New Features and Changes
  3. PowerExchange Installation and Upgrade
  4. PowerExchange Agent
  5. PowerExchange Client for PowerCenter
  6. PowerExchange Condense
  7. PowerExchange Listener
  8. PowerExchange Logger for Linux, UNIX, and Windows
  9. PowerExchange Navigator
  10. PowerExchange Monitoring and Tuning
  11. PowerExchange Utilities
  12. PowerExchange for Adabas
  13. PowerExchange for CA Datacom
  14. PowerExchange for DB2 for i
  15. PowerExchange for DB2 for Linux, UNIX, and Windows
  16. PowerExchange for DB2 for z/OS
  17. PowerExchange for CA IDMS
  18. PowerExchange for IMS
  19. PowerExchange for Microsoft SQL Server
  20. PowerExchange for MySQL
  21. PowerExchange for Oracle
  22. PowerExchange for PostgreSQL
  23. PowerExchange for VSAM and Flat Files
  24. PowerExchange ODBC

Ability to Specify Restart Tokens for a Database Row Test

Ability to Specify Restart Tokens for a Database Row Test

When you perform a database row test in the PowerExchange Navigator with a
DB Type
value of
CAPX
or
CAPXRT
, you can now specify restart tokens to control the point in the change stream from which the row test begins fetching data. Use this feature whenever you want to bypass some change records, for example, old records that have been archived off disk or records that are not consistent with an updated extraction map.
In the
Database Row Test
dialog box, click the
Advanced
button. Then on the
General
tab of the
CAPX Advanced Parameters
dialog box or
CAPXRT Advanced Parameters
dialog box, specify the sequence token in the
Restart Token 1
field and specify the restart token in the
Restart Token 2
field.
You can generate token values that identify the current end of the change stream from the PowerExchange Navigator or with the DTLUAPPL utility.
For more information, see the "Database Row Test" chapter in the
PowerExchange Navigator User Guide
.

0 COMMENTS

We’d like to hear from you!