Table of Contents

Search

  1. Preface
  2. Understanding Domains
  3. Managing Your Account
  4. Using Informatica Administrator
  5. Using the Domain View
  6. Domain Management
  7. Nodes
  8. High Availability
  9. Connections
  10. Connection Properties
  11. Schedules
  12. Domain Object Export and Import
  13. License Management
  14. Monitoring
  15. Log Management
  16. Domain Reports
  17. Node Diagnostics
  18. Understanding Globalization
  19. Appendix A: Code Pages
  20. Appendix B: Custom Roles
  21. Appendix C: Informatica Platform Connectivity
  22. Appendix D: Configure the Web Browser

Administrator Guide

Administrator Guide

Troubleshooting for Code Page Relaxation

Troubleshooting for Code Page Relaxation

The PowerCenter Integration Service failed a session and wrote the following message to the session log:
TM_6188 The specified sort order is incompatible with the PowerCenter Integration Service code page.
If you want to validate code pages, select a sort order compatible with the PowerCenter Integration Service code page. If you want to relax code page validation, configure the PowerCenter Integration Service to relax code page validation in Unicode data movement mode.
I tried to view the session or workflow log, but it contains garbage characters.
The PowerCenter Integration Service is not configured to write session or workflow logs using the UTF-8 character set.
Enable the LogsInUTF8 option in the PowerCenter Integration Service properties.

0 COMMENTS

We’d like to hear from you!