Table of Contents

Search

  1. Preface
  2. Analyst Service
  3. Catalog Service
  4. Content Management Service
  5. Data Integration Service
  6. Data Integration Service Architecture
  7. Data Integration Service Management
  8. Data Integration Service Grid
  9. Data Integration Service REST API
  10. Data Integration Service Applications
  11. Enterprise Data Preparation Service
  12. Interactive Data Preparation Service
  13. Informatica Cluster Service
  14. Mass Ingestion Service
  15. Metadata Access Service
  16. Metadata Manager Service
  17. Model Repository Service
  18. PowerCenter Integration Service
  19. PowerCenter Integration Service Architecture
  20. High Availability for the PowerCenter Integration Service
  21. PowerCenter Repository Service
  22. PowerCenter Repository Management
  23. PowerExchange Listener Service
  24. PowerExchange Logger Service
  25. SAP BW Service
  26. Search Service
  27. System Services
  28. Test Data Manager Service
  29. Test Data Warehouse Service
  30. Web Services Hub
  31. Application Service Upgrade
  32. Appendix A: Application Service Databases
  33. Appendix B: Connecting to Databases from Windows
  34. Appendix C: Connecting to Databases from UNIX or Linux
  35. Appendix D: Updating the DynamicSections Parameter of a DB2 Database

Application Service Guide

Application Service Guide

Configuring ODBC Connectivity

Configuring ODBC Connectivity

You can configure ODBC connectivity to a Teradata database.
The following steps provide a guideline for configuring ODBC connectivity. For specific instructions, see the database documentation.
  1. Create an ODBC data source for each Teradata database that you want to access.
    To create the ODBC data source, use the driver provided by Teradata.
    Create a System DSN if you start the Informatica service with a
    Local System account
    logon. Create a User DSN if you select the
    This account
    log in option to start the Informatica service.
  2. Enter the name for the new ODBC data source and the name of the Teradata server or its IP address.
    To configure a connection to a single Teradata database, enter the DefaultDatabase name. To create a single connection to the default database, enter the user name and password. To connect to multiple databases, using the same ODBC data source, leave the DefaultDatabase field and the user name and password fields empty.
  3. Configure Date Options in the Options dialog box.
    In the Teradata Options dialog box, specify AAA for DateTime Format.
  4. Configure Session Mode in the Options dialog box.
    When you create a target data source, choose ANSI session mode. If you choose ANSI session mode, Teradata does not roll back the transaction when it encounters a row error. If you choose Teradata session mode, Teradata rolls back the transaction when it encounters a row error. In Teradata mode, the Integration Service cannot detect the rollback and does not report this in the session log.
  5. Verify that you can connect to the Teradata database.
    To test the connection, use a Teradata client program, such as WinDDI, BTEQ, Teradata Administrator, or Teradata SQL Assistant.