Table of Contents

Search

  1. Preface
  2. Analyst Service
  3. Catalog Service
  4. Content Management Service
  5. Data Integration Service
  6. Data Integration Service Architecture
  7. Data Integration Service Management
  8. Data Integration Service Grid
  9. Data Integration Service REST API
  10. Data Integration Service Applications
  11. Enterprise Data Preparation Service
  12. Interactive Data Preparation Service
  13. Informatica Cluster Service
  14. Mass Ingestion Service
  15. Metadata Access Service
  16. Metadata Manager Service
  17. Model Repository Service
  18. PowerCenter Integration Service
  19. PowerCenter Integration Service Architecture
  20. High Availability for the PowerCenter Integration Service
  21. PowerCenter Repository Service
  22. PowerCenter Repository Management
  23. PowerExchange Listener Service
  24. PowerExchange Logger Service
  25. SAP BW Service
  26. Search Service
  27. System Services
  28. Test Data Manager Service
  29. Test Data Warehouse Service
  30. Web Services Hub
  31. Application Service Upgrade
  32. Appendix A: Application Service Databases
  33. Appendix B: Connecting to Databases from Windows
  34. Appendix C: Connecting to Databases from UNIX or Linux
  35. Appendix D: Updating the DynamicSections Parameter of a DB2 Database

Application Service Guide

Application Service Guide

Configuration Properties

Configuration Properties

To edit the configuration properties, select the Metadata Manager Service in the Navigator, select the
Properties
view, and then click
Edit
in the Configuration Properties section.
The following table describes the configuration properties for a Metadata Manager Service:
Property
Description
URLScheme
Indicates the security protocol that you configure for the Metadata Manager application: HTTP or HTTPS.
Keystore File
Keystore file that contains the keys and certificates required if you configure a secure connection for the Metadata Manager web application. You must use the same security protocol for the Metadata Manager Agent if you install it on another machine.
Keystore Password
Password for the keystore file.
MaxConcurrentRequests
Maximum number of request processing threads available, which determines the maximum number of client requests that Metadata Manager can handle simultaneously. Default is 100.
MaxQueueLength
Maximum queue length for incoming connection requests when all possible request processing threads are in use by the Metadata Manager application. Metadata Manager refuses client requests when the queue is full. Default is 500.
You can use the MaxConcurrentRequests property to set the number of clients that can connect to Metadata Manager. You can use the MaxQueueLength property to set the number of client requests Metadata Manager can process at one time.
You can change the parameter values based on the number of clients that you expect to connect to Metadata Manager. For example, you can use smaller values in a test environment. In a production environment, you can increase the values. If you increase the values, more clients can connect to Metadata Manager, but the connections might use more system resources.

0 COMMENTS

We’d like to hear from you!