Table of Contents

Search

  1. Preface
  2. Analyst Service
  3. Catalog Service
  4. Content Management Service
  5. Data Integration Service
  6. Data Integration Service Architecture
  7. Data Integration Service Management
  8. Data Integration Service Grid
  9. Data Integration Service REST API
  10. Data Integration Service Applications
  11. Enterprise Data Preparation Service
  12. Interactive Data Preparation Service
  13. Informatica Cluster Service
  14. Mass Ingestion Service
  15. Metadata Access Service
  16. Metadata Manager Service
  17. Model Repository Service
  18. PowerCenter Integration Service
  19. PowerCenter Integration Service Architecture
  20. High Availability for the PowerCenter Integration Service
  21. PowerCenter Repository Service
  22. PowerCenter Repository Management
  23. PowerExchange Listener Service
  24. PowerExchange Logger Service
  25. SAP BW Service
  26. Search Service
  27. System Services
  28. Test Data Manager Service
  29. Test Data Warehouse Service
  30. Web Services Hub
  31. Application Service Upgrade
  32. Appendix A: Application Service Databases
  33. Appendix B: Connecting to Databases from Windows
  34. Appendix C: Connecting to Databases from UNIX or Linux
  35. Appendix D: Updating the DynamicSections Parameter of a DB2 Database

Application Service Guide

Application Service Guide

Configuring Service Process Variables for Multiple Nodes

Configuring Service Process Variables for Multiple Nodes

When you configure the PowerCenter Integration Service to run on a grid or a backup node, all PowerCenter Integration Service processes associated with a PowerCenter Integration Service must use the same shared directories for PowerCenter Integration Service files.
Configure service process variables with identical absolute paths to the shared directories on each node that is configured to run the PowerCenter Integration Service. If you use a mounted drive or a mapped drive, the absolute path to the shared location must also be identical.
For example, if you have a primary and a backup node for the PowerCenter Integration Service, recovery fails when nodes use the following drives for the storage directory:
  • Mapped drive on node1: F:\shared\Informatica\<infa_version>\infa_shared\Storage
  • Mapped drive on node2: G:\shared\Informatica\<infa_version>\infa_shared\Storage
Recovery also fails when nodes use the following drives for the storage directory:
  • Mounted drive on node1: /mnt/shared/Informatica/<infa_version>/infa_shared/Storage
  • Mounted drive on node2: /mnt/shared_filesystem/Informatica/<infa_version>/infa_shared/Storage
To use the mapped or mounted drives successfully, both nodes must use the same drive.