Release Notes (10.4.1.2)

Release Notes (10.4.1.2)

Update the Input.properties File

Update the Input.properties File

The
Input.properties
file includes properties that identify the Informatica installation and define the action taken when you run the service pack installer. Update the properties before you install or roll back the service pack. Update the file in each service package that you download.
  1. Extract the service pack file.
  2. Find the
    Input.properties
    file in the service pack.
  3. Update the
    DEST_DIR
    property in the file with the path to the Informatica root directory.
    • On a Linux machine, set the path in the following format:
      DEST_DIR=/home/infauser/<version number>
    • On a Windows machine, set the path in the following format:
      DEST_DIR=C:\\Informatica\\<version number>
  4. Configure the value of the ROLLBACK property. You can apply or roll back the service pack for all product components or to specific component. To install the service pack, retain the default value of
    0
    . To roll back the service pack, set the value to
    1
    .
    When you install or roll back the service pack, the installer applies all the components, by default.
    To install or roll back a specific component in the service pack:
    • Remove the comment tag (#) associated with the component that you want to apply.
    • For Data Engineering component, set BDM_ONLY to 1.
    • For Enterprise Data Catalog, set EDC_ONLY to 1.
    • For Enterprise Data Preparation, set EDP_ONLY to 1
    Data Privacy Management requires Data Engineering and Enterprise Data Catalog components. For Data Privacy Management, remove the comment tag (#) associated with Data Engineering, Enterprise Data Catalog, and Data Privacy Management, and set the values to 1.
    You must apply individual components in the following order if you have multiple products installed:
    1. Data Engineering products
    2. Enterprise Data Catalog
    3. Enterprise Data Preparation
    4. Data Privacy Management
    You must roll back the components for a customized product application in the following order:
    1. Enterprise Data Preparation
    2. Enterprise Data Catalog
    3. Data Engineering products
    4. Data Privacy Management
    For Enterprise Data Catalog, if you configured Data Asset Analytics, run the following scripts located in the
    <Informatica Installation Directory>/services/CatalogService/DAABackupScripts/{DB_TYPE}/
    directory to roll back to 10.4.1:
    • 10412_metatable_rollback.sql
    • 10412_seeddata_rollback.sql
    • 10411_rollback.sql
    If you created an
    Asset Usage
    report, the report continues to be available with the following issues after the rollback:
    • The report continues to exist in the list of reports that you can create in the
      New Report
      dialog box after the rollback. However, you cannot use the report option to create a valid
      Asset Usage
      report.
    • On the
      Reports
      page, you can view the asset usage reports that you had created, but you cannot view or download the report from the
      Monitoring
      page.
    After a rollback, the
    Auto Enrichment
    column in the
    Asset Enrichment
    ,
    Data Domain Association
    , and
    Business Term Association
    reports continue to display the new status values.
  5. Save and close the file.

0 COMMENTS

We’d like to hear from you!