Table of Contents

Search

  1. Preface
  2. Command Line Programs and Utilities
  3. Installing and Configuring Command Line Utilities
  4. Using the Command Line Programs
  5. Environment Variables for Command Line Programs
  6. Using infacmd
  7. infacmd as Command Reference
  8. infacmd aud Command Reference
  9. infacmd autotune Command Reference
  10. Infacmd bg Command Reference
  11. infacmd ccps Command Reference
  12. infacmd cluster Command Reference
  13. infacmd cms Command Reference
  14. infacmd dis Command Reference
  15. infacmd dp Command Reference
  16. infacmd idp Command Reference
  17. infacmd edp Command Reference
  18. Infacmd es Command Reference
  19. infacmd ihs Command Reference
  20. infacmd ipc Command Reference
  21. infacmd isp Command Reference
  22. infacmd ldm Command Reference
  23. infacmd mas Command Reference
  24. infacmd mi Command Reference
  25. infacmd mrs Command Reference
  26. infacmd ms Command Reference
  27. infacmd oie Command Reference
  28. infacmd ps Command Reference
  29. infacmd pwx Command Reference
  30. infacmd roh Command Reference
  31. infacmd rms Command Reference
  32. infacmd rtm Command Reference
  33. infacmd sch Command Reference
  34. infacmd search Command Reference
  35. infacmd sql Command Reference
  36. infacmd tdm Command Reference
  37. infacmd tools Command Reference
  38. infacmd wfs Command Reference
  39. infacmd ws Command Reference
  40. infacmd xrf Command Reference
  41. infacmd Control Files
  42. infasetup Command Reference
  43. pmcmd Command Reference
  44. pmrep Command Reference
  45. Working with pmrep Files

runSpec

runSpec

Runs a mass ingestion specification that is deployed to a Data Integration Service. Before you can run a specification, you must deploy the specification using infacmd mi deploySpec.
The infacmd mi runSpec command uses the following syntax:
runSpec <-DomainName|-dn> domain_name <-UserName|-un> user_name <-Password|-pd> password [<-SecurityDomain|-sdn> security_domain] <-ServiceName|-sn> service_name <-MISpecName|-spec> mi_spec_name [<-LoadType|-lt> load_type] <-DISServiceName|-dsn> dis_service_name [<-OperatingSystemProfile|-osp> operating_system_profile_name]
The following table describes infacmd mi runSpec options and arguments:
Option
Argument
Description
-DomainName
-dn
domain_name
Required. Name of the Informatica domain. You can set the domain name with the -dn option or the environment variable INFA_DEFAULT_DOMAIN. If you set a domain name with both methods, the -dn option takes precedence.
-UserName
-un
user_name
Required. User name to connect to the domain. You can set the user name with the -un option or the environment variable INFA_DEFAULT_DOMAIN_USER. If you set a user name with both methods, the -un option takes precedence.
-Password
-pd
password
Required. Password for the user name. The password is case sensitive. You can set a password with the -pd option or the environment variable INFA_DEFAULT_DOMAIN_PASSWORD. If you set a password with both methods, the password set with the -pd option takes precedence.
-SecurityDomain
-sdn
security_domain
Optional. Name of the security domain to which the domain user belongs. You can set a security domain with the -sdn option or the environment variable INFA_DEFAULT_SECURITY_DOMAIN. If you set a security domain name with both methods, the -sdn option takes precedence. The security domain name is case sensitive.
Default is Native.
-ServiceName
-sn
service_name
Required. Name of the Mass Ingestion Service that manages the mass ingestion specification.
-MISpecName
-spec
mi_spec_name
Required. Name of the mass ingestion specification that is deployed to the Data Integration Service.
-LoadType
-lt
load_type
Optional. Type of load to ingest the data in the mass ingestion specification. Use
full
or
incremental
. Default is
full
.
If incremental load is not enabled in the mass ingestion specification, you cannot use an incremental load to ingest the data.
-DISServiceName
-dis
data_integration_service
Required. Name of the Data Integration Service where the mass ingestion specification is deployed.
-OperatingSystemProfile
-osp
operating_system_profile_name
Optional. Name of the operating system profile configured for the Data Integration Service.

0 COMMENTS

We’d like to hear from you!