Table of Contents

Search

  1. Preface
  2. Analyst Service
  3. Catalog Service
  4. Content Management Service
  5. Data Integration Service
  6. Data Integration Service Architecture
  7. Data Integration Service Management
  8. Data Integration Service Grid
  9. Data Integration Service REST API
  10. Data Integration Service Applications
  11. Data Privacy Management Service
  12. Enterprise Data Preparation Service
  13. Interactive Data Preparation Service
  14. Informatica Cluster Service
  15. Mass Ingestion Service
  16. Metadata Access Service
  17. Metadata Manager Service
  18. Model Repository Service
  19. PowerCenter Integration Service
  20. PowerCenter Integration Service Architecture
  21. High Availability for the PowerCenter Integration Service
  22. PowerCenter Repository Service
  23. PowerCenter Repository Management
  24. PowerExchange Listener Service
  25. PowerExchange Logger Service
  26. SAP BW Service
  27. Search Service
  28. System Services
  29. Test Data Manager Service
  30. Test Data Warehouse Service
  31. Web Services Hub
  32. Application Service Upgrade
  33. Appendix A: Application Service Databases
  34. Appendix B: Connecting to Databases from Windows
  35. Appendix C: Connecting to Databases from UNIX or Linux
  36. Appendix D: Updating the DynamicSections Parameter of a DB2 Database

Configuring Monitoring Model Repository Service

Configuring Monitoring Model Repository Service

Specify a Model repository when you configure the monitoring settings to store run-time statistics about objects that the Data Integration Services run.
  1. Log in to Informatica Administrator.
  2. Navigate to the
    Manage
    Services and Nodes
    view.
  3. In the
    Domain Navigator
    , select the domain.
  4. In the
    Domain
    view, click the
    Monitoring Configuration
    view.
    The default monitoring configuration parameters appear.
  5. Click the
    Edit
    icon.
    The
    Monitoring Configuration
    dialog box appears.
  6. You can edit the following options depending on your requirements:
    Option
    Description
    Model Repository Service
    Name of the monitoring Model repository that stores the historical information. The monitoring Model repository must not be integrated with a version control system.
    Username
    User name to access the monitoring Model Repository Service. Does not appear in domains that use Kerberos authentication.
    Password
    Password to access the monitoring Model Repository Service. Does not appear in domains that use Kerberos authentication.
    Modify Password
    Modify the monitoring Model Repository Service password.
    Security Domain
    Name of the security domain that the monitoring Model repository user belongs to.
    Preserve Summary Historical Data
    Number of days that the monitoring Model repository saves averaged data. If purging is disabled, then the monitoring Model repository saves the data indefinitely.
    Default is 180. Minimum is 0. Maximum is 366.
    Preserve Detailed Historical Data
    Number of days that the monitoring Model repository saves per-minute data. If purging is disabled, then the monitoring Model repository saves the data indefinitely.
    Default is 14. Minimum is 1. Maximum is 14.
    Purge Statistics Every
    Interval, in days, at which the monitoring Model Repository Service purges data that is older than the values configured in the Preserve Historical Data option.
    Default is 1 day.
    Days At
    Time of day when the monitoring Model Repository Service purges statistics. Default is 1:00 a.m.
    Maximum Number of Sortable Records
    Maximum number of records that can be sorted in the Monitor tab. If the number of records on the Monitor tab is greater than this value, then you can only sort by Start Time and End Time.
    Default is 3,000.
    Maximum Delay for Update Notifications
    Maximum time, in seconds, that the Data Integration Service buffers statistics before it stores them in the monitoring Model repository and displays them in the Monitor tab. If the Data Integration Service shuts down unexpectedly before it stores the statistics in the monitoring Model repository, then the statistics are lost.
    Default is 10.
    Date Time Field
    Include milliseconds for date and time fields in the
    Monitor
    tab.
  7. Click
    OK
    .
To apply the settings, you must restart all of the Data Integration Services.