Table of Contents

Search

  1. Preface
  2. Upgrade Overview
  3. Before You Upgrade the Domain on Linux
  4. Prepare for the Upgrade
  5. Upgrade the Domain
  6. Upgrade the Domain with Changes to Node Configuration
  7. Application Service Upgrade
  8. Informatica Client Upgrade
  9. Appendix A: Upgrade Checklist
  10. Appendix B: Managing Distribution Packages

Upgrading from Version 10.2.2 (10.5.5)

Upgrading from Version 10.2.2 (10.5.5)

Step 2. Verify Port Requirements

Step 2. Verify Port Requirements

The installer sets up the ports for components in the Informatica domain, and it designates a range of dynamic ports to use for some application services.
You can specify the port numbers to use for the components and a range of dynamic port numbers to use for the application services. Or you can use the default port numbers provided by the installer. Verify that the port numbers are available on the machines where you install the Informatica services.
The following table describes the ports that you can set:
Port
Description
Service Manager port
Port number used by the Service Manager on the node. The Service Manager listens for incoming connection requests on this port. Client applications use this port to communicate with the services in the domain. The Informatica command line programs use this port to communicate to the domain. This is also the port for the SQL data service JDBC/ODBC driver. Default is 6006.
Service Manager Shutdown port
Port number that controls server shutdown for the domain Service Manager. The Service Manager listens for shutdown commands on this port. Default is 6007.
Informatica Administrator port
Port number used by Informatica Administrator. Default is 6008.
Informatica Administrator HTTPS port
No default port. Enter the required port number when you create the service. Setting this port to 0 disables an HTTPS connection to the Administrator tool.
Informatica Administrator shutdown port
Port number that controls server shutdown for Informatica Administrator. Informatica Administrator listens for shutdown commands on this port. Default is 6009.
Minimum port number
Lowest port number in the range of dynamic port numbers that can be assigned to the application service processes that run on this node. Default is 6014.
Maximum port number
Highest port number in the range of dynamic port numbers that can be assigned to the application service processes that run on this node. Default is 6114.
Services and nodes can fail to start if there is a port conflict. You can update the range of ports for application services after you upgrade.