Common Content for Data Engineering
- Common Content for Data Engineering 10.5.6
- All Products
upgradeWorkflowParameterFile <-DomainName|-dn> domain_name <-ServiceName|-sn> service_name <-UserName|-un> user_name <-Password|-pd> password [<-SecurityDomain|-sdn> security_domain] [<-ResilienceTimeout|-re> timeout_period_in_seconds] <-Application|-a> application_name <-Workflow|-wf> workflow_name <-ParameterFile|-pf> parameter file path <-TargetOutputFile|-of> output_file_path
Option
| Argument
| Description
|
---|---|---|
-DomainName
-dn
| domain_name
| Required. Name of the Informatica domain. You can set the domain name with the -dn option or the environment variable INFA_DEFAULT_DOMAIN. If you set a domain name with both methods, the -dn option takes precedence.
|
-ServiceName
-sn
| service_name
| Required. Name of the Data Integration Service to run the workflow. The application that contains the workflow must be deployed to a Data Integration Service.
|
-UserName
-un
| user_name
| Required if the domain uses Native or LDAP authentication. User name to connect to the domain. You can set the user name with the -un option or the environment variable INFA_DEFAULT_DOMAIN_USER. If you set a user name with both methods, the -un option takes precedence.
Optional if the domain uses Kerberos authentication. To run the command with single sign-on, do not set the user name. If you set the user name, the command runs without single sign-on.
|
-Password
-pd
| password
| Required if you specify the user name. Password for the user name. The password is case sensitive. You can set a password with the -pd option or the environment variable INFA_DEFAULT_DOMAIN_PASSWORD. If you set a password with both methods, the password set with the -pd option takes precedence.
|
-SecurityDomain
-sdn
| security_domain
| Required if the domain uses LDAP authentication. Optional if the domain uses native authentication or Kerberos authentication. Name of the security domain to which the domain user belongs. You can set a security domain with the -sdn option or the environment variable INFA_DEFAULT_SECURITY_DOMAIN. If you set a security domain name with both methods, the -sdn option takes precedence. The security domain name is case sensitive.
If the domain uses native or LDAP authentication, the default is Native. If the domain uses Kerberos authentication, the default is the LDAP security domain created during installation. The name of the security domain is the same as the user realm specified during installation.
|
-ResilienceTimeout
-re
| timeout_period_in_seconds
| Optional. Amount of time in seconds that infacmd attempts to establish or re-establish a connection to the domain. You can set the resilience timeout period with the -re option or the environment variable INFA_CLIENT_RESILIENCE_TIMEOUT. If you set the resilience timeout period with both methods, the -re option takes precedence.
|
-Application
-a
| application_name
| Required. Name of the application that contains the workflow.
|
-Workflow
-wf
| workflow_name
| Required. Name of the workflow that reads the values parameter file.
|
-Wait
-w
| true|false
| Optional. Indicates whether infacmd waits for the workflow instance to complete before returning to the shell or command prompt. If true, infacmd returns to the shell or command prompt after the workflow instance completes. You cannot run subsequent commands until the workflow instance completes. If false, infacmd returns to the shell or command prompt immediately. You do not have to wait for the workflow instance to complete before running the next command. Default is false.
|
-ParameterFile
-pf
| parameter file path
| Required. Name and location of the parameter file that contains the values to upgrade.
|
-TargetOutputFile
-of
| parameter file path
| Required. Name and location of the output file from the command. The output file contains the valid parameters for the current release.
|