What's New and Changed (10.5.1.1)

What's New and Changed (10.5.1.1)

PowerExchange Adapters for PowerCenter

PowerExchange Adapters for PowerCenter

This section describes changes to PowerCenter adapters in version 10.2 HotFix 2.

PowerExchange for Google Analytics

Effective in version 10.2 HotFix 2, PowerExchange for Google Analytics installs with the Informatica services.
Previously, PowerExchange for PowerExchange for Google Analytics had a separate installer.
For more information, see the
Informatica PowerExchange for Google Analytics 10.2 HotFix 2 User Guide for PowerCenter
.

PowerExchange for Google Cloud Spanner

Effective in version 10.2 HotFix 2, PowerExchange for Google Cloud Spanner installs with the Informatica services.
Previously, PowerExchange for PowerExchange for Google Cloud Spanner had a separate installer.
For more information, see the
Informatica PowerExchange for Google Cloud Spanner 10.2 HotFix 2 User Guide for PowerCenter
.

PowerExchange for Google Cloud Storage

Effective in version 10.2 HotFix 2, PowerExchange for Google Cloud Spanner installs with the Informatica services.
Previously, PowerExchange for PowerExchange for Google Cloud Spanner had a separate installer.
For more information, see the
Informatica PowerExchange for Google Cloud Spanner 10.2 HotFix 2 User Guide for PowerCenter
.

PowerExchange for Kafka

Effective in version 10.2 HotFix 2, PowerExchange for Kafka installs with the Informatica services.
Previously, PowerExchange for PowerExchange for Kafka had a separate installer.
For more information, see the
Informatica PowerExchange for Kafka 10.2 HotFix 2 User Guide for PowerCenter
.

PowerExchange for MongoDB

Effective in version 10.2 HotFix 2, the Schema Editor is no longer available in the following directory:
Informatica installation directory>/clients/tools/mongodb/Tools
To use the Schema Editor on a Windows machine, apply the Informatica EBF-13871.
For more information, see the
Informatica PowerExchange for MongoDB 10.2 HotFix 2 User Guide for PowerCenter
.

PowerExchange for Salesforce

Effective in version 10.2 HotFix 2, the null values in the source are treated as null in the target.
Previously, the null values in the source were treated as false in the target.
For more information, see the
Informatica PowerExchange for Salesforce 10.2 HotFix 2 User Guide for PowerCenter
.

PowerExchange for Snowflake

Effective in version 10.2 HotFix 1, PowerExchange for Snowflake has the following changes:
  • You can override the database and schema name used while importing the tables through the Snowflake connection. To override, enter the database and schema name in the
    Additional JDBC URL Parameters
    field in the Snowflake connection properties in the following format:
    DB=<DB_name>&Schema=<schema_name>
    Previously, you could specify an override for the database and schema name only in the session properties.
  • You can read or write data that is case-sensitive or contains special characters. You cannot use the following special characters: @ ~ \
    Previously, you had to ensure that the source and target table names contained only uppercase letters.
  • PowerExchange for Snowflake uses the Snowflake JDBC driver version 3.6.26.
    Previously, PowerExchange for Snowflake used the Snowflake JDBC driver version 3.6.4.
  • When you run a custom query to read data from Snowflake, the Integration Service runs the query and the performance of importing the metadata is optimized.
    Previously, when you configured a custom query to read data from Snowflake, the Integration Service sent the query to the Snowflake endpoint and the number of records to import was limited to 10 records.
For more information, see the
Informatica PowerExchange for Snowflake 10.2 HotFix 2 User Guide for PowerCenter
.

PowerExchange for Teradata Parallel Transporter API

Effective in 10.2 HotFix 2, you can run a Teradata ODBC mapping on the AIX machine. You must install the Teradata ODBC driver version 16.20.00.50 or later when you use the Teradata client version 16.20.x.
Previously, you could not run a Teradata ODBC mapping on the AIX machine when you used the Teradata ODBC driver versions earlier than 16.20.00.50.