Release Notes

Release Notes

Known Limitations

Known Limitations

CR
Description
DIHD-1431
When you import an Informatica Intelligent Cloud Service (IICS) Custom or Modular publication or subscription, the task doesn't overwrite successfully.
Workaround: Set the conflict-resolution of workflows in the user interface settings to "Overwrite".
DIHD-1036
After you change the default file group on the
Data Integration Hub
publication repository, when you edit a topic that was created before the change, a message informs you that unconsumed data that was published from the topic will be discarded.
Topics that existed before you changed the default file group continue to publish to the file group that was the default group when the topic was created. Changing the default file group does not discard unconsumed data that was published before the change.
DIHD-1032
For publications with a publication pre-process, the Event Average Processing Time report does not calculate the pre-processing time.
DIHD-1020
Subscription runs fail when the subscription contains a filter for a column with a
TEXT
data type with a
Does Not Equal
operator and the option
Use pushdown optimization
is enabled for the subscription.
DIHD-1018
When you change the default data storage location on the publication repository, a warning message appears, stating that the storage location has changed and that the topic tables will be recreated. The topic metadata is changed and holds the new default storage location. Topic tables are not recreated on the new storage location, and remain on the old storage location.
Workaround: Edit the topic and change the Data Storage Location to the new default data storage location on the publication repository.
XE-8752
Microsoft SQL database where partitioning is enabled: If the retention period of a topic is set to one day
Data Integration Hub
cannot delete the topic data from the publication repository. Only data that is older than one day is moved onto the partition.
Workaround: Set topic retention period for two or more days.
XE-8333
When you use a database password that ends with the # character,
Data Integration Hub
enters the password into the PowerCenter connection without the # character.
XE-7153
Data Integration Hub
stores operational data store JDBC connection properties in the dx-configuration.properties file in addition to
Data Integration Hub
system properties.
Workaround: If you change the JDBC connection properties in the dx-configuration.properties file, change the system properties.

0 COMMENTS

We’d like to hear from you!