PowerCenter
- PowerCenter H2L
- All Products
Bug
| Description
|
---|---|
OCON-9730
| The Simba MongoDB ODBC driver fails to support the _ID colum, if present in an array element or nested document.
Simba MongoDB ODBC driver reference number: 00093670
|
OCON-9718
| The Simba MongoDB ODBC driver treats the MongoDB Views as read only tables.
Simba MongoDB ODBC driver reference number: 00094915
|
OCON-9710
| The Simba MongoDB ODBC driver does not support query override feature when parent table and virtual table are used together in a MongoDB source.
|
OCON-9706
| The Simba MongoDB ODBC driver does not support Unicode metadata.
Simba MongoDB ODBC driver reference number: 00094913
|
OCON-9699
| When you select the
Refresh Schema option for a virtual table in a MongoDB source and use the
Mapping flow option to write data to a virtual table in a MongoDB target, the mapping fails.
|
OCON-9697
| The Simba MongoDB ODBC driver fails to create the target table as the driver does not support
Drop Table and
Create Table commands.
|
OCON-9695
| When you refresh a schema for a MongoDB connection in the Connection Explorer view of the Developer tool or in PowerCenter, the Simba MongoDB ODBC driver fails to refresh the schema in the table.
Workaround: Disconnect the connection and re-connect to list the table.
Simba MongoDB ODBC driver reference number: 00094912
|
CON-8147
| When you use the Simba MongoDB ODBC driver, you cannot read or write records in JSON format.
Simba MongoDB ODBC driver reference number: 00094516
|
CON-7530
| When you use the Simba MongoDB ODBC driver to connect to MongoDB, you cannot truncate the target table.
Simba MongoDB ODBC driver reference number: 00092615
|
CON-2347
| You cannot use Mongo shell commands in preprocessing and postprocessing commands, and in saved and custom queries of a task to write data to MongoDB.
Simba MongoDB ODBC driver reference number: 00094260
|