Fixed Issues

Fixed Issues

The following table describes fixed issues:
Bug
Description
PWX-9962
The number of SVCNODE statements allowed in a DBMOVER configuration file is limited to 10.
PWX-9889
If the TRACING statement in the DBMOVER file enables alternative logging, the PowerExchange Listener might stop responding if a subtask cannot open the next alternative log file during a file switch.
PWX-9876
If you have Db2 for Linux, UNIX, and Windows version 11.5 sources, you cannot run the DTLUCUDB utility or capture change data on Linux.
PWX-9837
PowerExchange cannot create capture registrations for Microsoft SQL Server source tables that include computed columns.
PWX-9831
Columns in extraction maps are not ordered by column ID. The column order in the extraction maps do not match the column order in the table DDL. During CDC processing, an error reports invalid capture data.
PWX-9806
PowerExchange Express CDC for Oracle processing of large transactions might degrade performance.
PWX-9805
PowerExchange Express CDC for Oracle CDC fails during dynamic dictionary processing with the following error because of an unnecessary check for MAXOBJ:
PWX-36000 ORAD: Internal error Unknown object past base of dictionary: OBJ: 502466 rdsDML.GetScn() 9095570242 MaxObj: 0 in module PwxOrlDictImpl:6693
This error might occur after an online reorg operation on the database or a change to the object IDs of the tables.
PWX-9755
The MySQL capture process consumes a lot of memory while processing large transactions.
PWX-9739
During multiple-record writes to a flat file, the CSQ_MEMSIZE attribute setting in the PowerExchange overrides is not honored.
PWX-9735
The PowerExchange Listener stops responding when tape data set volumes cannot be mounted.
PWX-9692
The Enterprise Data Catalog (EDC) Scanner fails with a wildcard character mismatch for an escape character error.
PWX-9677
Unbounded tracing of table control blocks can occur after PowerExchange captures the first DML change for a Db2 for z/OS table.
PWX-9666
On IBM i, the PowerExchange Listener cannot identify the stored procedure and fails with the following message:
PWX-00999 Program logic error. Prog="DTLDB2Y". Line=2419. P1="Ordinal 2 already in list. Name IN". P2=2.
PWX-9659
The PowerExchange Listener might encounter excessive wait times when tape data set volumes cannot be mounted.
PWX-9608
While PowerExchange gathers diagnostics after a log processing failure, an ABEND0C4 abend might occur at X029030+3E4 in the Db2 for z/OS ECCR.
PWX-9547
BI/CI fields are not populated correctly during PostgreSQL CDC processing of an Update operation.
PWX-9546
If you use the RECONNTRIES and RECONNWAIT parameters in the PG CAPI_CONNECTION statement for PostgreSQL CDC, capture processing abends.
PWX-9541
A NULL value was found for a column that is not nullable in a source table. This issue occurs when a table name or any column name is longer than 30 characters.
PWX-9509
The PostgreSQL CDC extraction process stops responding when a connection to a database on Linux is lost.
PWX-9508
During PowerExchange Express CDC for Oracle processing, the PowerExchange Logger misses rows for source indexed-organized tables (IOTs) using ARRAY INSERT operations.
PWX-9466
If you run a Db2 for z/OS bulk data movement job with the mode type NOSUBMIT, the generated JCL template does not contain the first line of JOB statement.