CONDF_VOL Parameter

CONDF_VOL Parameter

The volume serial number (VOLSER) for condense files.
CONDF_FULL_FILE_CTL
CONDF_VOL=
volser
For the
volser
variable, enter a z/OS VOLSER.
  • Do not specify the CONDF_VOL parameter with the CONDF_FULL_FILE_CTL parameter for a full condense. If you specify both parameters, PowerExchange issues error message PWX-06308.
  • Do not specify the CONDF_VOL parameter with the CONDF_PART_STORCLAS parameter for a partial condense. If you specify both parameters, PowerExchange issues error message PWX-06308.