PowerExchange Interfaces for PowerCenter

PowerExchange Interfaces for PowerCenter

Configuring Connection and Network Operation Timeouts

Configuring Connection and Network Operation Timeouts

Use this procedure to override the default connection timeout or to enable a network operations timeout.
To configure connection and network operation timeouts:
  1. In the Workflow Manager, connect to a PowerCenter repository.
  2. Complete one of the following actions:
    • Click
      Connections > Relational
      .
    • Click
      Connections > Application
      .
    The
    Relational Connection Browser
    dialog box or
    Application Connection Browser
    dialog box appears.
  3. In the
    Select Type
    field, select the type of connection for which you want to configure timeouts.
  4. Click
    Edit
    or
    New
    , based on whether you are creating or editing a connection.
    The
    Connection Object Definition
    dialog box appears.
  5. Scroll to the
    PWX Override
    connection attribute. In the
    Value
    column, specify the number of seconds for the connection timeout interval, network operation timeout interval, or both.
    If you specify both overrides, in either order, separate them with a semicolon. Use the following syntax:
    TCPIP_OP_TIMEOUT=
    network_operation_timeout
    ;TCPIP_CON_TIMEOUT=
    connection_timeout
  6. Click
    OK
    .