PWX- 27025

PWX-
27025

Reason
hexadecimal_reason_code
: Logger could not find a registration by the listener connection
The PowerExchange Logger for z/OS did not find a capture registration based on the resource interest list from a PowerExchange Listener.
If the reason code is A0B0019, this problem can occur for the following reasons:
  • Multiple PowerExchange Listeners were accessing the same CCT file. One of these PowerExchange Listeners was updating registration information but it was not the one that the PowerExchange Agent was using.
  • The PowerExchange Agent refresh interval is too long. After a registration is created, updated, or deleted, the PowerExchange Agent does not refresh the registration information in the CCT file soon enough for the PowerExchange Logger to use it.
Processing ends abnormally.
For more information, see the related messages.