Table of Contents

Search

  1. Preface
  2. PowerExchange Installation and Upgrade Overview
  3. Installation Planning
  4. Upgrade Planning
  5. Installing and Upgrading PowerExchange on IBM i
  6. Installing and Upgrading PowerExchange on Linux and UNIX
  7. Installing and Upgrading PowerExchange on Windows
  8. Installing and Upgrading PowerExchange on z/OS
  9. Appendix A: Upgrade Considerations
  10. Appendix B: PowerExchange Environment
  11. Appendix C: Manual Installation on IBM i

Installation and Upgrade Guide

Installation and Upgrade Guide

Create Runlib JCL Page

Create Runlib JCL Page

Enter information to create the RUNLIB JCL.
RUNLIB
The fully-qualified name of the RUNLIB library to which the z/OS Installation Assistant transfers the installation JCL, except for an upgrade that uses existing data set names. You must preallocate this library. When the z/OS Installation Assistant creates the installation JCL, it uses this RUNLIB name to customize the JCL.
For a first-time installation, the default value is PWX.RUNLIB.
For an upgrade that uses existing data set names, this library must be the RUNLIB library in the currently running PowerExchange environment and must be different from the staging RUNLIB data set name. When the z/OS Installation Assistant creates the JCL that is written to the staging RUNLIB library, the z/OS Installation Assistant uses this name to customize the JCL. The z/OS Installation Assistant does not update this library.
For an upgrade that uses new data set names, the default value is
hlq
.RUNLIB, where
hlq
is the value entered on the
Data Set Group Details
page.
For a hotfix installation, the default value is PWX.SP.RUNLIB. Verify that this data set name does not match the RUNLIB data set name that the current PowerExchange environment uses.
For a full install or an upgrade, this setting corresponds to the <runlib> variable in the INSTPARM file. For a hotfix install, this setting corresponds to the <patchrunlib> variable in the INSTPARM file.
BINLIB
The fully-qualified name of the BINLIB library to which the z/OS Installation Assistant transfers modules and load libraries, except for an upgrade using existing data set names. The z/OS Installation Assistant uses this name to customize the installation JCL. You must preallocate this library.
For a first-time installation, the default value is PWX.BINLIB. When the z/OS Installation Assistant creates the installation JCL, it uses this name to customize the JCL.
For an upgrade that uses existing data set names, this library must be the BINLIB library in the currently running PowerExchange environment and must be different from the staging BINLIB data set name. The z/OS Installation Assistant does not update this library.
For an upgrade that uses new data set names, the default value is
hlq
.BINLIB, where
hlq
is the value entered on the
Data Set Group Details
page.
For a hotfix installation, the default value is PWX.SP.BINLIB. Verify that this data set name does not match the BINLIB data set name that the current PowerExchange environment uses.
For a full install or an upgrade, this setting corresponds to the <binlib> variable in the INSTPARM file. For a hotfix install, this setting corresponds to the <patchbinlib> variable in the INSTPARM file.
The following Pages are incomplete or contain data validation errors...
This message box displays the names of any wizard pages that are incomplete or contain validation errors.
GoTo Page
When you select a page name in the validation errors message window, goes to the page where the validation error is located.
Restore Defaults
Restores default values.