PowerExchange for CDC and Mainframe
- PowerExchange for CDC and Mainframe 10.5.6
- All Products
Attribute
| Required or Optional
| Description
|
---|---|---|
Location
| Required
| The node name of the PowerExchange Listener. This value must match the node name in a NODE statement in the PowerExchange DBMOVER configuration file on the system where the database resides.
|
User Name
| Required
| A user name that has the authority to connect to the source database.
For sources on supported Linux, UNIX, or Windows systems, if you have enabled PowerExchange LDAP user authentication, the user name is the enterprise user name. For more information, see the
PowerExchange Reference Manual .
|
Password
| Required
| A password for the specified user. Passwords that are less than nine characters in length are not validated.
To avoid errors that might arise due to code page differences, Informatica recommends that the password includes only those characters that are allowed for passphrases.
For access to i5/OS or z/OS, you can enter a valid PowerExchange passphrase instead of a password. An i5/OS passphrase can be from 9 to 31 characters in length. A z/OS passphrase can be from 9 to 128 characters in length when using PWXPC. A passphrase can contain the following characters:
Passphrases cannot include single quotation marks (‘), double quotation marks (“), or currency symbols.
On z/OS, the allowable characters in the IBM IRRPHREX exit do not affect the allowable characters in PowerExchange passphrases.
On z/OS, a valid RACF passphrase can be up to 100 characters in length. PWXPC truncates passphrases longer than 100 characters when passing them to RACF for validation.
To use passphrases, ensure that the PowerExchange Listener runs with a security setting of SECURITY=(1,N) or higher in the DBMOVER member. For more information, see "SECURITY Statement" in the
PowerExchange Reference Manual .
|
Multi-Record Datamaps
| -
| Select this option to list multi-record data maps. SEQ or VSAM sources only.
|
Source Type
| Required
| Select one of the following source types:
|
CDC Datamaps
| Required
| Select this option to list CDC extraction maps.
|
Network Timeout
| Optional
| The number of seconds that must elapse during a network send or receive operation before PowerExchange ends the connection and issues a timeout error message.
|
Schema
| Optional
| A schema name that is used to filter the extraction maps.
|
Map name
| Optional
| A map name that is used to filter the extraction maps.
|
Respect Case
| Optional
| Select this option to have PowerExchange treat the schema and map name filter values in a case-sensitive manner when searching for extraction maps. When this option is cleared, PowerExchange ignores the case of the filter values.
|