Table of Contents

Search

  1. Preface
  2. Part 1: Introduction
  3. Part 2: PowerExchange Client for PowerCenter (PWXPC)
  4. Part 3: PowerExchange ODBC
  5. Appendix A: PowerExchange Interfaces for PowerCenter Tips
  6. Appendix B: Datatypes and Code Pages
  7. Appendix C: PowerExchange Interfaces for PowerCenter Troubleshooting

PowerExchange Interfaces for PowerCenter

PowerExchange Interfaces for PowerCenter

Connection Attributes for Multiple-Record Writes

Connection Attributes for Multiple-Record Writes

When you create a connection for a source or target in a workflow that performs multiple-record writes, observe the following rules and guidelines:
  • You can use multiple-record writes with PWXPC connections only. Multiple-record writes with PowerExchange ODBC connections are not supported.
  • Select
    Filter After
    for the
    Offload Processing
    source and target connection attribute. PowerExchange and PWXPC perform offload processing on the Integration Service machine.
    If you select a different value for
    Offload Processing
    , PowerExchange changes the value to
    Filter After
    .
    However, if RBAs are being read using the GetDatabaseKey or GetIMSRBAByLevel function from an IMS unload file in the BMC LONG format, you must select
    No
    for the
    Offload Processing
    source connection attributes. Otherwise, the session will fail with message PWX-03803.
  • Multithreaded processing is supported for IMS source connections if you select
    Filter After
    for the
    Offload Processing
    connection attribute and set the
    Worker Threads
    connection attribute to a non-zero value.
  • Multithreaded mapping processing is not supported for IMS target connections. If you set the
    Worker Threads
    connection attribute to a non-zero value, the session ignores this setting.
  • Multithreaded processing is not supported for sequential or VSAM connections.
  • Multithreaded processing is not supported for sequential or VSAM source or target connections.
    If you set the
    Worker Threads
    connection attribute to a nonzero value, the setting is ignored.
  • Select
    Off
    for the
    Confirm Write
    source and target connection properties. If you select a different value, PowerExchange changes the value to
    Off
    .
  • In certain cases, you might need to change the value of the
    CSQ_MEMSIZE
    parameter of the
    PWX Override
    connection property. This property defines the maximum amount of memory that the cache can consume for multiple-record writes.

0 COMMENTS

We’d like to hear from you!