Table of Contents

Search

  1. Preface
  2. Analyst Service
  3. Catalog Service
  4. Content Management Service
  5. Data Integration Service
  6. Data Integration Service Architecture
  7. Data Integration Service Management
  8. Data Integration Service Grid
  9. Data Integration Service REST API
  10. Data Integration Service Applications
  11. Enterprise Data Preparation Service
  12. Interactive Data Preparation Service
  13. Informatica Cluster Service
  14. Mass Ingestion Service
  15. Metadata Access Service
  16. Metadata Manager Service
  17. Model Repository Service
  18. PowerCenter Integration Service
  19. PowerCenter Integration Service Architecture
  20. High Availability for the PowerCenter Integration Service
  21. PowerCenter Repository Service
  22. PowerCenter Repository Management
  23. PowerExchange Listener Service
  24. PowerExchange Logger Service
  25. SAP BW Service
  26. Search Service
  27. System Services
  28. Test Data Manager Service
  29. Test Data Warehouse Service
  30. Web Services Hub
  31. Application Service Upgrade
  32. Appendix A: Application Service Databases
  33. Appendix B: Connecting to Databases from Windows
  34. Appendix C: Connecting to Databases from UNIX or Linux
  35. Appendix D: Updating the DynamicSections Parameter of a DB2 Database

Application Service Guide

Application Service Guide

Configuring the PowerCenter Integration Service Operating Mode

Configuring the PowerCenter Integration Service Operating Mode

You can use the Administrator tool to configure the PowerCenter Integration Service to run in safe mode, run in normal mode, or run in safe or normal mode on failover. To configure the operating mode on failover, you must have the high availability option.
When you change the operating mode on fail over from safe to normal, the change takes effect immediately.
  1. In the Administrator tool, click the
    Manage
    tab >
    Services and Nodes
    view.
  2. In the Domain Navigator, select a PowerCenter Integration Service.
  3. Click the Properties view.
  4. Go to the Operating Mode Configuration section and click Edit.
  5. To run the PowerCenter Integration Service in normal mode, set OperatingMode to Normal.
    To run the service in safe mode, set OperatingMode to Safe.
  6. To run the service in normal mode on failover, set OperatingModeOnFailover to Normal.
    To run the service in safe mode on failover, set OperatingModeOnFailover to Safe.
  7. Click OK.
  8. Restart the PowerCenter Integration Service.
The PowerCenter Integration Service starts in the selected mode. The service status at the top of the content pane indicates when the service has restarted.

0 COMMENTS

We’d like to hear from you!