Table of Contents

Search

  1. Preface
  2. Analyst Service
  3. Catalog Service
  4. Content Management Service
  5. Data Integration Service
  6. Data Integration Service Architecture
  7. Data Integration Service Management
  8. Data Integration Service Grid
  9. Data Integration Service REST API
  10. Data Integration Service Applications
  11. Data Privacy Management Service
  12. Enterprise Data Preparation Service
  13. Interactive Data Preparation Service
  14. Informatica Cluster Service
  15. Mass Ingestion Service
  16. Metadata Access Service
  17. Metadata Manager Service
  18. Model Repository Service
  19. PowerCenter Integration Service
  20. PowerCenter Integration Service Architecture
  21. High Availability for the PowerCenter Integration Service
  22. PowerCenter Repository Service
  23. PowerCenter Repository Management
  24. PowerExchange Listener Service
  25. PowerExchange Logger Service
  26. SAP BW Service
  27. Search Service
  28. System Services
  29. Test Data Manager Service
  30. Test Data Warehouse Service
  31. Web Services Hub
  32. Application Service Upgrade
  33. Appendix A: Application Service Databases
  34. Appendix B: Connecting to Databases from Windows
  35. Appendix C: Connecting to Databases from UNIX or Linux
  36. Appendix D: Updating the DynamicSections Parameter of a DB2 Database

Application Service Guide

Application Service Guide

Blocking Data

Blocking Data

You can include multiple input group transformations in a mapping. The DTM passes data to the input groups concurrently. However, sometimes the transformation logic of a multiple input group transformation requires that the DTM block data on one input group while it waits for a row from a different input group.
Blocking is the suspension of the data flow into an input group of a multiple input group transformation. When the DTM blocks data, it reads data from the source connected to the input group until it fills the reader and transformation buffers. After the DTM fills the buffers, it does not read more source rows until the transformation logic allows the DTM to stop blocking the source. When the DTM stops blocking a source, it processes the data in the buffers and continues to read from the source.
The DTM blocks data at one input group when it needs a specific row from a different input group to perform the transformation logic. After the DTM reads and processes the row it needs, it stops blocking the source.

0 COMMENTS

We’d like to hear from you!