The Extractor requested Microsoft SQL PID from the database server but received a null PID that is not valid. The Extractor disables processing of the online transaction logs.
Verify that the source database user has sufficient privileges to select data from the system tables. After you resolve the database-related issue, restart the Extractor to enable processing of the online transaction logs.