Data Archive
- Data Archive 6.4.3 HotFix 1
- All Products
Issue
| Description
|
---|---|
DA-5074
| If the number of legal holds at the table or row level exceeds the maximum limit, the table may become inaccessible with the error "Invalid LEGALHOLD serialization stream." The maximum limit at table level is 256 and at row level is 32.
|
DA-5072
| The export and import jobs in the application migration process fail when SSL is enabled.
Workaround: Before you use the application migration process, update the Data Vault Data Archive plugin. Pre-pend the odbc32 directory, where 32-bit SSL modules reside, to the LD_LIBRARY_PATH/LIBPATH. For example:
LD_LIBRARY_PATH=$1/webapp/file_archive/odbc:$1/webapp/file_archive$1/webapp/file_archive/odbc32:$LD_LIBRARY_PATH
LIB_PATH=$1/webapp/file_archive/odbc:$1/webapp/file_archive/odbc32:$LIB_PATH
|
DA-5064
| Salesforce archiving: The driver throws an "java.net.SocketException" exception while deleting records from tables when the tables have a large number of records.
Workaround: Resume the job in Data Archive.
|
DA-5029
| Salesforce archiving: The currency datatype value will be rounded off if it is created with high range precision.
|
DA-5028
| Salesforce archiving: Text Area (Rich) or HTML fields that contain an image will not be archived.
|
DA-5027
| Salesforce archiving: Creating interim tables in Salesforce is not supported if "Namespace" prefix is configured in Salesforce.
Workaround: give the interim schema as "PUBLIC" instead of "SFORCE." The "PUBLIC" value will create a table in the local database.
|
DA-5026
| Salesforce archiving: Primary key constraints name (PK_NAME) is not unique in different Enterprise Data Manager instances or different driver databases.
Workaround: Salesforce JDBC driver creates local database files like <Driver_Database>.config, <Driver_ Database>. properties, etc. in computer-1 while mining. Copy those configuration files into computer-2 and mine the same table.
|
DA-5025
| Salesforce archiving: Polymorphic relationships will not be mined in the Enterprise Data Manager.
Workaround: Once objects are mined, you can create logical foreign key constraints between child and parent tables.
|
DA-4956
| The test JDBC connectivity standalone job fails for Data Vault.
|
DA-4897
| If the number of domains or tables in a schema or database is very large, the ssacleanup utility might take a long time or hang when cleaning the entire schema or database.
|
DA-4883
| A select query with aggregation may report an incorrect result when non-grouping columns are part of select list.
|
DA-4732
| When you try to run existing reports, they will fail if you run the reports directly from Data Visualization Designer or "Advanced Reporting" on the new SSL-enabled environment.
Workaround: For Data Visualization Designer, modify the JDBC URL with SSL=1.
For Advanced Reporting, first run the report from Reports and Dashboards or Patient Archives, then run from Advanced Reporting.
|
DA-4035
| The Data Vault Loader Job fails when Dynamic Data Masking connection details are used in the target connection.
Workaround: While running the loader, change the target connection port in