Test Data Management
- Test Data Management 10.5.2
- All Products
Property
| Description
|
---|---|
Name
| Required. Name of the connection. The name is not case sensitive and must be unique within the domain. It cannot exceed 128 characters, start with a number, contain spaces, or contain the following special characters:
~ ` ! $ % ^ & * ( ) - + = { [ } ] | \ : ; " ' < , > . ? /
|
Connection Type
| Required. The connection type. Select PWX NRDB Batch.
|
Description
| The description of the connection. The description cannot exceed 255 characters.
|
User Name
| Required. The database user name.
|
Password
| Required. The password for the database user name.
|
Owner
| The owner of the connection. Default is the user who creates the connection. You can change the owner of the connection.
|
Code Page
| The code page that the Integration Service uses to extract data from the source database.
In Unicode mode, PWXPC sets the code page with this value overriding any code page specification in the PowerExchange configuration file.
|
Array Size
| Storage array size, in number of records, that is used for partitioned or multithreaded sessions. For partitioned sessions, this array size is shared across the partitions. Valid values are from 1 through 100000.
Default is 25.
To tune partitioned sessions, particularly when the Write Mode attribute specifies Confirm Write On, increase the array size.
|
Write Mode
| Mode in which the Integration Service sends data to the PowerExchange Listener. Configure one of the following write modes:
Default is Confirm Write On.
|
Off Load Processing
| Controls whether to use offload processing. Offload processing transfers PowerExchange bulk data processing from the source system to the Integration Service machine. Select one of the following values:
Default is No.
|
Worker Threads
| The number of threads that PowerExchange uses on the Integration Service machine to process bulk data. For optimal performance, this value should not exceed the number of installed or available processors on the Integration Service machine. Valid values are from 1 through 64.
Default is 0, which disables multithreading. If you use reader or writer pipeline partitioning, accept the default value of 0. You cannot use both multiple worker threads and partitioning.
|
Connection Retry Period
| Number of seconds the Integration Service attempts to reconnect to the data source or target if the connection fails. If the Integration Service cannot connect to the database in the retry period, the operation fails.
Default is 0.
|
Compression
| Select to compress source data during the PowerCenter session.
Default is disabled.
|
Encryption Type
| The type of encryption that the Integration Service uses. Select one of the following values:
|
Encryption Level
| The level of encryption that the Integration Service uses. If you select RC2 or DES for Encryption Type, select one of the following values to indicate the encryption level.
Default is 1.
|
Interpret As Rows
| Interprets the pacing size as rows or kilobytes. Select to represent the pacing size in number of rows. If you clear this option, the pacing size represents kilobytes.
Default is disabled.
|
Convert Character Data As String
| Convert character fields to string fields so that embedded nulls in data are processed as spaces.
Default is disabled.
|
PWX Override
| PowerExchange connection override values, separated by semicolons. You can enter any of the following overrides:
If you use write partitioning and set the Write Mode attribute to Confirm Write On, you can specify WRT_ERROR_HANDLIN=Y to use an alternative method of error handling that is more efficient than the default method when the input data contains many errors. You can also specify this statement in the dbmover.cfg configuration file.
|
Pacing Size
| Amount of data that the source system can pass to the PowerExchange Listener. Configure the pacing size if an external application, database, or the Integration Service node is a bottleneck. The lower the value, the faster the performance. Enter 0 for maximum performance.
Default is 0.
|
Location
| Required. Location of the PowerExchange Listener node. The location is defined in the first parameter of the NODE statement in the PowerExchange dbmover.cfg configuration file.
|
Get PowerExchange Log Entries
| Specifies whether PWXPC writes PowerExchange messages related to a CDC session in the PowerCenter session log.
Default is disabled.
|