Table of Contents

Search

  1. Preface
  2. Analyst Service
  3. Catalog Service
  4. Content Management Service
  5. Data Integration Service
  6. Data Integration Service Architecture
  7. Data Integration Service Management
  8. Data Integration Service Grid
  9. Data Integration Service Applications
  10. Interactive Data Preparation Service
  11. Enterprise Data Preparation Service
  12. Informatica Cluster Service
  13. Mass Ingestion Service
  14. Metadata Access Service
  15. Metadata Manager Service
  16. Model Repository Service
  17. PowerCenter Integration Service
  18. PowerCenter Integration Service Architecture
  19. High Availability for the PowerCenter Integration Service
  20. PowerCenter Repository Service
  21. PowerCenter Repository Management
  22. PowerExchange Listener Service
  23. PowerExchange Logger Service
  24. SAP BW Service
  25. Search Service
  26. System Services
  27. Test Data Manager Service
  28. Test Data Warehouse Service
  29. Web Services Hub
  30. Application Service Upgrade
  31. Appendix A: Application Service Databases
  32. Appendix B: Connecting to Databases from Windows
  33. Appendix C: Connecting to Databases
  34. Appendix D: Updating the DynamicSections Parameter of a DB2 Database

Configuring ODBC Connectivity

Configuring ODBC Connectivity

You can configure ODBC connectivity to a Netezza database.
The following steps provide a guideline for configuring ODBC connectivity. For specific instructions, see the database documentation.
  1. Create an ODBC data source for each Netezza database that you want to access.
    To create the ODBC data source, use the driver provided by Netezza.
    Create a System DSN if you start the Informatica service with a Local System account logon. Create a User DSN if you select the This account log in option to start the Informatica service.
    After you create the data source, configure the properties of the data source.
  2. Enter a name for the new ODBC data source.
  3. Enter the IP address/host name and port number for the Netezza server.
  4. Enter the name of the Netezza schema where you plan to create database objects.
  5. Configure the path and file name for the ODBC log file.
  6. Verify that you can connect to the Netezza database.
    You can use the Microsoft ODBC Data Source Administrator to test the connection to the database. To test the connection, select the Netezza data source and click Configure. On the Testing tab, click Test Connection and enter the connection information for the Netezza schema.