Table of Contents

Search

  1. Preface
  2. Introduction to Data Integration Hub
  3. Security
  4. Events
  5. User Policies
  6. Operation Console Management
  7. System Properties
  8. Connections
  9. Connectivity to Informatica Intelligent Cloud Services
  10. Integration of Data Integration Hub with Enterprise Data Catalog
  11. Document Management
  12. Entity Management
  13. Export and Import
  14. Data Integration Hub Utilities
  15. Dashboard and Reports Management

Administrator Guide

Administrator Guide

Dashboard and Reports System Properties

Dashboard and Reports System Properties

After you install the Dashboard and Reports component, you can use system properties to modify certain aspects of the Dashboard behavior.
The following table describes the Dashboard and reports system properties:
System Property
Description
dx.dashboard.url
Connection string to the dashboard server, in the following format:
http://<hostname>:<port>/<dashboard name>
If you use HTTPS to connect to the Operation Console, the URL must match the value of the property. Otherwise, the Dashboard does not appear.
For example:
https://myhost:18443/
dih
-dashboard
dx.dashboard.max.timewindow
Maximum time frame in hours that Operation Console users can select to display unresolved error events in the Dashboard.
Default is 96.
dx.dashboard.jdbc.username
User name for the operational data store database.
dx.dashboard.jdbc.password
Password for the operational data store in an encrypted string database. If you change the password you must encrypt the string with the password encryption utility and use the encrypted string.
dx.dashboard.jdbc.url
Location of operational data store. The location must be different from the
Data Integration Hub
repository.
dx.dashboard.errorrate.threshold.low
For internal use only. Do not change the default value.
dx.dashboard.errorrate.threshold.high
For internal use only. Do not change the default value.
dx.dashboard.sla.detection.midnight.latency
For internal use only. Do not change the default value.
dx.first.day.of.week
For internal use only. Do not change the default value.
dx.ods.latency.seconds
Number of seconds between the time the event finished processing and the time that the event load process starts. The operational data store event loader loads events for which the processing time difference in seconds is equal or greater than this value. For example, if you increase the latency to 60 seconds, the event loader only loads events that finished processing at least 60 seconds before the load process starts.
Default is 0.
dx.ods.row.limit.thousands
Number of thousands of events to load in each batch when the total number of events is higher than this value. If the total number of events to load is less than the value in this property, the operational data store event loader runs one batch. If you set the row limit to 0, the event loader runs one batch regardless of the number of events.
Default is 500. Must be numeric and greater than or equal to 0.

0 COMMENTS