CDCPUB_ 14006

CDCPUB_
14006

The table [
table_name
] contains characters that are not valid for an Avro schema. Avro field names must begin with a letter and include only the digits 0-9, letters A-Z and a-z, and underscore (_) character. Consider changing the current replacement character [
replacement_character
].
The table name is used to create an Avro field name. Avro field names must begin with an alphabetic character A-Z or a-z and can contain the digits 0-9, letters A-Z and a-z, and the underscore (_) character. If a replacement character is defined, it will replace any non-conforming characters in the table name before the name is passed to Avro.
Verify that you defined a replacement character that can be used to replace any special characters in the table name. If you suspect that the current replacement character is not supported by Avro, try changing the replacement character. If the problem persists, contact Informatica Global Customer Support.