Table of Contents

Search

  1. Preface
  2. Part 1: PowerExchange Change Data Capture Introduction
  3. Part 2: CDC Components Configuration and Management
  4. Part 3: CDC Sources Configuration and Management
  5. Part 4: Change Data Extraction
  6. Part 5: Monitoring and Tuning
  7. Appendix A: CDC for z/OS Troubleshooting
  8. Appendix B: DTL__CAPXTIMESTAMP Time Stamps

Enabling Capture Registrations for PowerExchange Condense Use

Enabling Capture Registrations for PowerExchange Condense Use

PowerExchange Condense captures and logs change data only for capture registrations that have a status of
Active
and a
Condense
setting of
Part
or
Full
.
  1. In the PowerExchange Navigator, open the capture registration.
  2. In the Resource Inspector, select
    Active
    from the
    Status
    list.
  3. From the
    Condense
    list, select
    Part
    or
    Full
    .
  4. Click
    Apply
    .
  5. Click
    File
    Save
    to save the capture registration. Alternatively, press CTRL+S.
You must refresh or recycle the ECCR that captures changes for the data source, and recycle the PowerExchange Condense job if it is running.
If PowerExchange Condense does not find any active capture registration, it issues the error message PWX-06427 and ends.

0 COMMENTS