Table of Contents

Search

  1. Preface
  2. Summary of PowerExchange New Features and Changes
  3. PowerExchange Installation and Upgrade
  4. PowerExchange Agent
  5. PowerExchange Client for PowerCenter
  6. PowerExchange Condense
  7. PowerExchange Listener
  8. PowerExchange Logger for Linux, UNIX, and Windows
  9. PowerExchange Navigator
  10. PowerExchange Monitoring and Tuning
  11. PowerExchange Utilities
  12. PowerExchange for Adabas
  13. PowerExchange for CA Datacom
  14. PowerExchange for DB2 for i
  15. PowerExchange for DB2 for Linux, UNIX, and Windows
  16. PowerExchange for DB2 for z/OS
  17. PowerExchange for CA IDMS
  18. PowerExchange for IMS
  19. PowerExchange for Microsoft SQL Server
  20. PowerExchange for MySQL
  21. PowerExchange for Oracle
  22. PowerExchange for PostgreSQL
  23. PowerExchange for VSAM and Flat Files
  24. PowerExchange ODBC

Db2 for z/OS ECCR Configuration Statements in the REPL2OPT DD Data Set

Db2 for z/OS ECCR Configuration Statements in the REPL2OPT DD Data Set

PowerExchange 10.4.1 introduces the following change to a configuration statement in the data set or RUNLIB member that is allocated by the REPL2OPT DD statement in the Db2 for z/OS ECCR JCL:
IFI306 [OPT={N|
Y
|F}] ...
Optional. Controls the Db2 ECCR interaction with the Db2 instrumentation facility interface (IFI). The default value for the OPT parameter has changed.
OPT
Specifies how the Db2 ECCR reads the Db2 log.
Valid values are:
  • Y
    . Recommended. Returns CDC records from the Db2 log.
  • N
    . Returns all records from the Db2 log.
  • F
    . Returns CDC records from the log and filters them by registered tables.
New default is Y.
For more information, see the "DB2 for z/OS Change Data Capture" chapter in the
PowerExchange CDC Guide for z/OS
.

0 COMMENTS