Table of Contents

Search

  1. Preface
  2. Part 1: PowerExchange Change Data Capture Introduction
  3. Part 2: CDC Components Configuration and Management
  4. Part 3: CDC Sources Configuration and Management
  5. Part 4: Change Data Extraction
  6. Part 5: Monitoring and Tuning
  7. Appendix A: CDC for z/OS Troubleshooting
  8. Appendix B: DTL__CAPXTIMESTAMP Time Stamps

CONDF_UNIT Parameter

CONDF_UNIT Parameter

The unit name of the device where PowerExchange Condense condense files reside.
CONDF_FULL_FILE_CTL
CONDF_UNIT=
unit_name
For the
unit_name
variable, enter a valid z/OS generic or esoteric unit name, such as 3390 or SYSDA.
  • Do not specify the CONDF_UNIT parameter with the CONDF_FULL_FILE_CTL parameter for a full condense. If you specify both parameters, PowerExchange issues error message PWX-06308.
  • Do not specify the CONDF_UNIT parameter with CONDF_PART_STORCLAS parameter for a partial condense. If you specify both parameters, PowerExchange issues error message PWX-06308.

0 COMMENTS

We’d like to hear from you!