NO_DATA_WAIT Parameter

NO_DATA_WAIT Parameter

The number of seconds that the Datacom table-based ECCR waits after it reads the Datacom CDC tables and finds no new changes before starting the next read operation.
During the next read operation, if the ECCR still finds no changes, the NO_DATA_WAIT2 interval takes effect.
NO_DATA_WAIT2
NO_DATA_WAIT={
60
|
seconds
}
For the
seconds
variable, enter a number of seconds greater than 0.
Default is 60.
During the wait interval, the ECCR waits simultaneously for console input.