Table of Contents

Search

  1. Preface
  2. Summary of PowerExchange New Features and Changes
  3. PowerExchange Installation and Upgrade
  4. PowerExchange Agent
  5. PowerExchange Client for PowerCenter
  6. PowerExchange Condense
  7. PowerExchange Listener
  8. PowerExchange Logger for Linux, UNIX, and Windows
  9. PowerExchange Navigator
  10. PowerExchange Monitoring and Tuning
  11. PowerExchange Utilities
  12. PowerExchange for Adabas
  13. PowerExchange for CA Datacom
  14. PowerExchange for DB2 for i
  15. PowerExchange for DB2 for Linux, UNIX, and Windows
  16. PowerExchange for DB2 for z/OS
  17. PowerExchange for CA IDMS
  18. PowerExchange for IMS
  19. PowerExchange for Microsoft SQL Server
  20. PowerExchange for MySQL
  21. PowerExchange for Oracle
  22. PowerExchange for PostgreSQL
  23. PowerExchange for SAP HANA
  24. PowerExchange for VSAM and Flat Files
  25. PowerExchange ODBC

Updated Components in the PowerExchange ECCR CRG.LOAD Library for IMS Synchronous CDC

Updated Components in the PowerExchange ECCR CRG.LOAD Library for IMS Synchronous CDC

PowerExchange 10.4.0 updates the PowerExchange CRG.LOAD library for IMS synchronous CDC to provide the latest available version of the BMC Software CHANGE RECORDING FACILITY, DATABASE INTEGRITY PLUS, or Fast Path Online Restructure/EP components.
You can use either the CRG software that PowerExchange delivers or one of these BMC Software products, which include the CRG code.
If you have a supported version of one of the BMC Software products, Informatica recommends that you use the BMC Software product instead of the CRG software.
  • If you use one of the BMC Software products, ensure that the product meets the minimum version that PowerExchange requires for IMS synchronous CDC, as described in the "IMS Synchronous Change Data Capture" chapter of the
    PowerExchange CDC Guide for z/OS
    .
    For IMS 15, PowerExchange 10.4.0 requires the following minimum versions of the BMC Software products:
    • CHANGE RECORDING FACILITY: Version 5.1.00 Level 1907 with BMC fix BQQ4590
    • DATABASE INTEGRITY PLUS: Version 5.1.00 Level 1907 with BMC fix BQQ4590
    • Fast Path Online Restructure/EP: Version 4.1.00 Level 1907 with BMC fix BQQ4590
    If you use an earlier product version, upgrade to the supported minimum version or later.
  • If you use the CRG software, after you upgrade PowerExchange, run the CRGUMOD or CRGCLINK job in the
    hlq
    .SAMPLIB library again to install DBRC modifications. Otherwise, events such as abends might cause change capture to fail in the DLIODDC
    x
    module when the IMS synchronous ECCR tries to capture changes for a source segment. After you run the CRGUMOD or CRGCLINK job, restart the IMS control region.

0 COMMENTS

We’d like to hear from you!