The following parameter was changed in the PowerExchange Logger configuration file, pwxccl.cfg:
IBMIJRNLOVRD=(JRN=
library
/
journal_name
, [FROMRCVR=
library
/
from_receiver
,] [TORCVR=
library
/
to_receiver
])
Changed
. An override Db2 for i library/journal value that is used when remote logging of Db2 for i source data to the PowerExchange Logger is configured. This parameter overrides the JOURNAL parameter value in the AS4J CAPI_CONNECTION statement for PowerExchange Logger processing only. To specify a range of override journal receivers, use both the FROMRCVR and TORCVR keywords.
Specify the restart and sequence tokens in the PWXCCL.CFG file for the override receivers.
FROMRCVR=
library
/
from_receiver
New
. Optional. Specifies the beginning of a valid sequence of override journal receivers associated with the journal receiver specified in the IBMIJRNLOVRD JRN parameter. If you specify the FROMRCVR parameter, you must also specify the TORCVR parameter.
TORCVR=
library
/
to_receiver
New
. Optional. Specifies the end of the range of a valid sequence of override journal receivers associated with the journal receiver specified in the IBMIJRNLOVRD JRN parameter.