Table of Contents

Search

  1. Preface
  2. Part 1: PowerExchange CDC Introduction
  3. Part 2: PowerExchange CDC Components
  4. Part 3: PowerExchange CDC Data Sources
  5. Part 4: Change Data Extraction
  6. Part 5: Monitoring and Tuning
  7. Appendix A: DTL__CAPXTIMESTAMP Time Stamps

CDC Guide for Linux, UNIX, and Windows

CDC Guide for Linux, UNIX, and Windows

Stopping Change Data Capture for a SAP HANA Source Table

Stopping Change Data Capture for a SAP HANA Source Table

You might want to stop change data capture for a SAP HANA source table if the table has been dropped, change activity no longer occurs on the table, or the data in the table is no longer of interest for CDC processing.
  1. In PowerExchange Navigator, open the capture registration and set the
    Status
    option to
    History
    .
    A capture registration that has a status of
    History
    cannot be activated again.
  2. Shut down the PowerExchange Logger for Linux, UNIX, and Windows and then warm start it.
    This step refreshes the registration information that the PowerExchange Logger uses.
  3. In PowerCenter, delete or update the CDC workflows to ensure that no workflow processes the removed table. If you use PowerExchange with Cloud Data Integration, stop the Data Integration mapping tasks or taskflows.

0 COMMENTS

We’d like to hear from you!