Stopping Change Data Capture for a SAP HANA Source Table
Stopping Change Data Capture for a SAP HANA Source Table
You might want to stop change data capture for a SAP HANA source table if the table has been dropped, change activity no longer occurs on the table, or the data in the table is no longer of interest for CDC processing.
In PowerExchange Navigator, open the capture registration and set the
Status
option to
History
.
A capture registration that has a status of
History
cannot be activated again.
Shut down the PowerExchange Logger for Linux, UNIX, and Windows and then warm start it.
This step refreshes the registration information that the PowerExchange Logger uses.
In PowerCenter, delete or update the CDC workflows to ensure that no workflow processes the removed table. If you use PowerExchange with Cloud Data Integration, stop the Data Integration mapping tasks or taskflows.