Performing a Cold Start for PowerExchange ECCR after a Datacom Source Database Reload

Performing a Cold Start for PowerExchange ECCR after a Datacom Source Database Reload

When the Datacom database has been refreshed or reloaded from another database, you must clear the TSN and MNT tables before performing an ECCR cold start.
  1. Stop all transactions from updating the source database that is to be reloaded.
  2. To clear the TSN and MNT tables of old data, run the CLEANUP process against the source database by specifying the CLEANUP parameter. For more information, see CLEANUP Parameter.
  3. Stop the ECCR.
  4. Load the source database.
  5. Cold start the ECCR.