Message Reference

PETL_ 24065

PETL_
24065

Error: Thread <thread name> exceeded the maximum wait time while waiting for a reply from the Master DTM.
A worker DTM process waited longer than the maximum amount of time allotted to wait for a reply from the master DTM process.
View the workflow log to see if the DTM process started on the node. If the DTM process started and shut down unexpectedly, the error is internal. If the error is not internal, contact the Network Administrator to verify that the network does not have connectivity issues. Contact the domain Administrator to verify that the Integration Service is running. Run the session again.