Starting the Adabas ECCR

Starting the Adabas ECCR

To start the Adabas ECCR, issue the MVS START command with the name of the started task, such as:
START PWXAD1EC
The Adabas ECCR can also be run as a batch job.
Start the Adabas ECCR after starting the PowerExchange, Listener, PowerExchange Agent, and PowerExchange Logger. The Adabas ECCR terminates with a return code 8 if there are no active Adabas capture registrations. PowerExchange issues messages about active registrations to the PowerExchange log file.
The Adabas ECCR issues message DTL07901 as a WTOR to the MVS operator console, requesting confirmation for cold start processing in the following cases:
  • The ECCR is being started for the first time
  • The ECCRNAME statement in the Adabas ECCR parameters specifies a new name for the Adabas ECCR
  • COLDSTART=Y is specified in the Adabas ECCR parameters