Table of Contents

Search

  1. Preface
  2. Part 1: PowerExchange Change Data Capture Introduction
  3. Part 2: CDC Components Configuration and Management
  4. Part 3: CDC Sources Configuration and Management
  5. Part 4: Change Data Extraction
  6. Part 5: Monitoring and Tuning
  7. Appendix A: CDC for z/OS Troubleshooting
  8. Appendix B: DTL__CAPXTIMESTAMP Time Stamps

NO_DATA_WAIT2 Parameter

NO_DATA_WAIT2 Parameter

After the NO_DATA_WAIT interval is no longer in effect, the number of seconds that the IMS log-based ECCR waits after an end-of-log condition before starting another log read operation.
During a read operation, if the ECCR captures changes, the NO_DATA_WAIT interval takes effect again. If the ECCR does not capture changes, it waits for the NO_DATA_WAIT2 interval and then tries the read again. The ECCR continues to wait for the NO_DATA_WAIT2 interval and retry the read on an ongoing basis, as long as no changes are available.
The ECCR checks the RECON data sets to determine whether a new LOG data set was registered.
NO_DATA_WAIT
NO_DATA_WAIT2={
600
|
seconds
}
For the
seconds
variable, enter a number from 1 to 99999999.
Default is 600.

0 COMMENTS

We’d like to hear from you!